Model: ODSHR42 2264 ODSHR Series Outdoor Woodburning Fireplace Underwriter's Laboratories Report No. MH20546 Homeowner's Installation & Operating Manual DO NOT DISCARD THIS MANUAL: Retain for future use. 20002264 2/03 Rev.
ODSHR Series Safety Information PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING FIREPLACE. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. NOTE: This unit is intended for outdoor use in the United States using CF11 or SK chimney systems. The unit may be installed indoors, in the U.S. only, using CF11 chimney system only.
ODSHR Series ODSHR42 Series Woodburning Fireplace ³⁄₄" Rough Opening Depth 62¹⁄₈" 35" 13³⁄₈" Dia. 10³⁄₈" 26³⁄₄" ³⁄₄" 11" Dia. ³⁄₄" 44⁹⁄₁₆" Rough Opening Width 53³⁄₄" 62¹⁄₈" Rough Opening Height 87⁷⁄₈" ³⁄₄" ³⁄₄" 12¹⁄₂" Outside Air 44" 15⁵⁄₈" 48¹⁄₄" 42" 13³⁄₄" 7³⁄₄" 24" Gas Line Access 7⁷⁄₁₆" 14¹⁄₂" Gas Line Access 52¹⁄₄" FP546A Fig. 1 ODSHR42 Series specifications and framing.
ODSHR Series Chase Installation Insulation methods shown are optional for cold climate, not a requirement for unit operation. Termination Cap Storm Collar Pan Flashing Batt Insulation (cut out around firestop) Draftstop Firestop Ceiling Level Ledge Bracket Surround Damper Control Gas Line Knockout (both sides) Gas Line Access (both sides) Screen Grate Firebox Metal Safety Strips (1,2 or 3) Outside Air Cover Plate FP554A Fig. 2 Fireplace and chase parts identification.
ODSHR Series Chimney Requirements - Offset Installations OFFSET CHIMNEY FLUE EXIT RISE CHIMNEY SECTION IWF282 B A D E 6 FT. G 30˚ OFFSET ELBOW RISE 30˚ RETURN ELBOW C H OFFSET 30˚ OFFSET ELBOW B 30˚ Elbow Offsets G 11CS SUPPORT H HEARTH FLOOR Example 1 Example 2 Notes: G + H cannot exceed 20 feet. *11CF Chimney airspace clearance = 2" minimum. Example 3 FP269 Illustration Key The following safety rules apply to offset installations (letters correspond with illustration above): C.
ODSHR Series Planning Information Preplanning an installation is very important to ensure safety and to save time and money. An installer must predetermine where a fireplace will be set and how the chimney system will be run. Mounting the Fireplace A fireplace may only be mounted on the following surfaces: 1. A flat combustible surface. 2. A raised wooden platform. 3. A concrete block or other solid object placed beneath each of the four (4) corners of the fireplace.
ODSHR Series Chimney Supports The chimney system is supported by the fireplace for vertical chimney heights less than 30 feet above the hearth. Chimney supports are required if the vertical height exceeds 30 feet with 11CF chimneys. Locate chimney supports at ceiling holes or other structural framing at 30 foot heights. Spacing between chimney supports must not exceed 30 feet. Use Chimney Support Model 11CS. (Note: The 11CS can not be mounted directly to the fireplace.
ODSHR Series 2. Framing Framing can be constructed before or after the fireplace is set in place, however, most installers build the frame before setting the fireplace. Frame fireplace with 2 x 4 lumber or heavier materials. Refer to framing dimensions in Figures 1, 2 or 3 for basic fireplace specifications. Note: Framing should be positioned to accommodate wall covering and fireplace facing material. 3.
ODSHR Series Cutting the Hole Cover fireplace collar opening and cut proper sized chimney hole in chimney. (Fig. 10 & 11) Existing Ceiling Joists 17¹⁄₂" 17¹⁄₂" Chimney Hole Framing the Ceiling Hole Frame the ceiling chimney hole as shown in Figure 11. It is good practice to use framing lumber that is the same size as the ceiling joists; this is a requirement at attic level.
ODSHR Series 4. Positioning, Safety Strips, Securing the Fireplace Slide fireplace into position. Metal Safety Strips (1, 2 or 3 pieces) Lift the fireplace front slightly and slide the metal safety strips under front bottom edge about 1¹⁄₂ inches, allowing the remainder to extend in front of firebox. Overlap strips at least 1/2 inch to provide a positive joint. (Flat safety strips are packed with fireplace.) (Fig.
ODSHR Series 5. Installing the Chimney System Pipe Section Start by attaching the first chimney section to the collar on top of the fireplace. UP Install the pipe as pictured in Figure 14. When you get a good lock, you will hear the pipe clearly snap together. Once sections are snap-locked in place, it is extremely difficult to get them apart. Make sure the pipe is firmly snapped and locked together as each pipe section is mounted.
ODSHR Series Firestop spacers are not available for, nor are they required on, vertical walls. materials such as: ceiling members, joists, flooring, combustible insulation and roof structures.) The Majestic Fireplaces' chimney components have been tested and approved with the area where the outer pipe slides through the firestop spacer sealed with a noncombustible caulk if desired, or left completely open with no sealant. WARNING: DO NOT PACK REQUIRED AIR SPACES WITH INSULATION OR OTHER MATERIALS.
ODSHR Series Air Space Clearances Flat Mantel Shelf Combustible framing material MUST NOT penetrate AIR SPACE (shaded areas) Stud 12" Min.
ODSHR Series Side Wall Protection Stud Finished Wall Adjacent combustible side walls that are within dimensions shown in Figure 24 of fireplace opening must be protected with Vermont Castings, Majestic Products Wall Shield Model SP40 or a specifically built wall shield described in Figure 22.
ODSHR Series Minimum Hearth Extension Dimensions Minimum Wall Clearances (for On-Site Construction) WITH Noncombustible Surround Facing WITHOUT Noncombustible Surround Facing Shaded area starts 3/4" away from edge of unit 4" 4" Brick (Example material) 20" 12" 12" 66" 18" 14"** 32¹⁄₂"** Side Wall Firebox Opening 18" 39¹⁄₂" 22" - Min. clearance to combustible perpendicular wall Side 18" - Min.
ODSHR Series Wall Covering COMMON MATERIALS AND FACTORS MATERIAL K* R MINIMUM THICKNESS 2 x 4 Header Do Not Notch at Ledge Brackets Fig. 18 EH2416 (Majestic Products Company) 0.458 1.09 0.50 in.** Hearth Extension Common Brick 5.0 0.10 5.46 in.** Hearth Extension Insulation Molding used to Fasten Hearth Extension in Place R Value is for ¹⁄₂ inch. * Units of K = BTU/SQ FT/HR/˚F/IN ** Thickness of Listed Material FP533ADD Majestic Safety Strips Must be Overlapped 1/2" Min. Fig.
ODSHR Series From inside the fireplace, locate the knockout on the firebrick -- be sure you are on the appropriate or "gas line" side of the fireplace. Using a flat bladed screwdriver or small chisel and hammer, carefully tap around the knockout until it loosens and falls out. Hole in Outer Casing Gas Line Tubing Install 1/2 inch certified gas pipe through opening. After gas pipe installation is complete, use insulation that was removed from gas line tube to repack space around the pipe.
ODSHR Series 1 2 4 9a,b 3 8 6 10 7 5 11 13 12 2264 Vermont Castings, Majestic Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. ODSHR Outdoor Woodburning Fireplace Ref. 1. 2. 3. 4. 5. 6. 7. 8. 9a. 9b. 10. 11. 12.
ODSHR Series Accessories The following accessories for this appliance are available from your local Vermont Castings, Majestic Products products distributor. Should you need additional information beyond what your distributor can furnish, contact: Vermont Castings, Majestic Products, 410 Admiral Blvd., Mississauga, Ontario, Canada L5T 2N6, Attn: Technical Services.
ODSHR Series Accessory Description Extended Round Top For use with Majestic Type "11CF" Chimney Systems. Used to terminate chimney at top of chase. Adapter kit included. Flashing not included. Chimney Sections Used to build "11CF" chimney systems. Chimney Elbows Used to develop 30° offset chimney systems. (Elbows packed 2 per carton upper and lower elbow set) Top Housing with Upper Baffle Gives traditional chimney top look using simulated brick in red, tan or white color.
ODSHR Series LIMITED WARRANTY & 30 YEAR PROTECTION PLAN For Vermont Castings, Majestic Products PRE-ENGINEERED Fireplace Systems Vermont Castings, Majestic Products warrants its Pre-Engineered Fireplace (“Fireplace”) and the Vermont Castings, Majestic Productssupplied firegrate, glass doors, outside air system, fan motor, and liners to be free from defects in material or workmanship, as follows: A.
ODSHR Series Vermont Castings, Majestic Products 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777 www.majesticproducts.com • www.vermontcastings.