User’s Guide and Important Warranty Information System Eco Range Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier.
Contents Section Natural Gas Main System 24 Eco G.C.No 41 467 11 Main System 28 Eco G.C.No 41 467 12 Page 1.0 Quick Reference Guide 3 2.0 Troubleshooting 4 3.0 Repressurising System 6 4.0 Clearances 7 5.0 Care of the Boiler 8 6.0 Legislation 9 7.0 Notes 10 8.0 Emergency 11 9.
1.0 Quick Reference Guide 2 Reset 1 3 4 0 bar ON/OFF/Reset Selector Switch Display Reset Central Heating Temperature Control Calibration Control Reset System Pressure Gauge Position of Optional Timer Reset OFF Position Central Heating & Hot Water Reset The boiler will not operate. Both Heating & Hot Water will operate. Hold for approx 5 seconds and release. Central Heating & Hot Water Indicator - The indicator will illuminate when the boiler is in the central heating mode.
Boiler not working 2.0 Troubleshooting START Make sure the gas supply is turned ON and check if other gas appliances are operating (e.g. fire, cooker). Is the ON/OFF/Reset Select Switch in the ( ) position ? YES NO Is the ( ( ) on ? YES ) light on and the NO Central Heating Indicator Reset If no gas, consult your supplier. Is the display lit ? YES Burner On Indicator Boiler operating satisfactorily. Display NO Check electricity to the boiler is switched on.
2.0 Troubleshooting Is the Timer ON and calling for heat ? 12 Is the Room Thermostat (if fitted) set high enough ? 10 15 20 25 4 8 5 3 9 2 5 6 7 Typical examples of external timer YES 1 10 11 YES CH ON CH OFF NO Turn Room Thermostat to maximum setting (typical example shown). NO 5 10 15 20 25 Ensure timer is set for Central Heating ON (see any instructions supplied with timer). CONTACT YOUR INSTALLER OR SERVICE ENGINEER.
3.0 Repressurising System 3.1 2 1 3 1. The normal operating water pressure is between 1 and 2.5 bar (Fig. 1). If the pressure exceeds 3 bar the safety pressure valve will operate and a fault is indicated. Contact your installer. 2. It may be necessary to repressurise the system occasionally (Fig. 2). A filling device (the filling loop) will be fitted on the system. This will be on the boiler itself, or on pipework near to the boiler. 4 0 Central Heating System Pressure bar Normal Pressure 3.
4.0 Clearances 450mm 5mm Min 5mm Min 200mm Min (300mm Min if using 80/125mm flueing system) 4.1 For your Safety 1. This appliance must have been installed in accordance with the manufacturer’s instructions and the regulations in force. 2. Any modification that may interfere with the normal operation of the appliance without express written permission from the manufacturer or his agent could invalidate the appliance warranty.
5.0 Care of the Boiler 5.1 Cleaning the Outer case The painted panels should be wiped with a damp cloth and then dried completely. DO NOT USE ABRASIVE CLEANING AGENTS. 5.2 Protection & Precaution 1. The boiler incorporates an integral frost protection feature that will operate in both modes. If the boiler temperature falls below 5° C, then the boiler will operate until the water temperature has been raised. 2.
6.0 Legislation 6.1 Installation, Commissioning, Service & Repair 1. This appliance must be install in accordance with the manufacturer’s instructions and the regulations in force. Read the instructions fully before installing or using the appliance. 2. In GB, this must be carried out by a competent person as stated in the Gas Safety (Installation & Use) Regulations. 3.
7.
8.0 Emergency Warning ! If you smell gas Turn off the gas supply at the meter and call your gas supplier immediately. It is possible to isolate the boiler at the isolating valve (Fig. 6). In GB, Transco operate a 24 hour emergency service and the telephone number will be listed in your telephone directory. Faulty boiler If it is known or suspected that a fault exists on the boiler, it must not be used until the fault has been corrected by a competent person.
Please complete the boxes below 9.0 Warranty & Service Serial Number Standard Warranty Term & Conditions 12 Months Free Warranty - register today To receive your 12 months free warranty please complete the form supplied with the boiler or simply call heateam, the service of Baxi Heating UK Ltd on 08706 000 653.