Technical data
1.3 
L 
Technical  Data 
Water inlet (Compression tYpe fittings)  .  . 
Water outlet (Compression type  fittings) 
Gas (Compression type  fittings)  . 
Height (including flue  bend) .  . . . 
Width 
.  . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Depth  .  .  .  . . . . . . . . . . . . . . . . . . . . . . . . . 
Weight.............................. 
Space for  fixing  - top (above flue) 
- bottom  (below case) 
-  sides  . . . . . . . . . . . . . 
-  front  .  .  . 
Hole for  the  air inlet duct  .  .  . 
The BRITONY II FF is supplied in one carton. 
97583 Btu/h 
76000 Btu/h 
94.3 ft3/h 
4.4 in.w.g. 
2 0.4 in.w.g. 
Heat input  nominal  . 
.  28.6 kW 
Heat output  nominal  .  .  . . .  . . . . .  . . 
22.4 kW 
Gas rate (maximum)  .  .  .  .  . 
2.67 ms/h 
Burner pressure  . . . . . . . . . . . . . . . . . . . . 
.  . . 
10.9 mbar 
Burner pressure tolerance  . 
2 1 .O mbar 
Main burner  injectors  .  .  .  . . 
. .  1.23 mm (stamped 1.23) 
Pilot injectors  . .  . .  . . . . . . . . . . . 
. .  0.23 mm (stamped 231 
Water flow  rate  - raised 50 ‘C (90 ‘F) . 
. . 
6.3 I/min  1.4 gpm 
Water flow  rate  - raised 30 “C (54 “F)  .  . . 
.  10.9 I/min  2.4 gpm 
Minimum operating  head  . . . . . . . . . 
.  7.5 m. 
25 ft  (  10 psi) 
Maximum operating  head  .  . . . .  .  .  . 
. .  100  m. 
328 ft  (I 50 psi) 
Electrical Connections - 240 V  50 Hz 
supply fused  3 A. 
The minimum  water pressure is for the  correct operation  of  the  appliance only. An additional  allowance must  be 
made for  the resistance  of  pipework and fittings  particularly  where showers  and washing  machines are  used. 
This should be equivalent to  2 m. (6.5 ft)  head. 
. 
. . 
. . 
. 
. . 
. 
. . 
. . 
. . 
. . 
. . 
. . 
. . 
15 mm Copper 
15 mm Copper 
15 mm Copper 
Right hand connection 
Left hand connection 
Centre connection 
778 mm (30.6 in) 
395 mm (15.5 in) 
270 mm (IO.6 in) 
20 kg. (42 lb) 
50 mm (  2 in) 
178 mm (  7 in) 
25 mm (  1 in) 
600 mm (24 in) 
107 mm (  4 in)  0 (diameter) 
1.4 
Flue  Length 
Minimum Wall Thickness 3 in (75 mm) 
Rear Outlet  Wall thickness 
Up to 612.5 mm 
Delivered with 
appliance 
Flue duct  length  = wall  thickness  + 25 mm 
Air inlet  duct length = wall  thickness  + 25 mm 
Over 
612.5 mm 
Extension available 
ptN”61061 
I 
Side Outlet 
EM = Wall thickness 
DM = Distance from wail to 
Rue 
Air  inlet  duct  length EM + DM + 130 mm 