Technical data
1. 
GENERAL 
The BRITONY II FF is a fanned  draught,  balanced flued  instantaneous  multipoint  appliance. The flue  is suitable for 
rear outlet, or to  either  side. The maximum recommended  flue  length  is 3 m. straight. 
The appliance is for  connection  to a mains cold water  supply only. 
A permanent  electrical  connection is required  and should be provided by use of  a fused  spur. The external  elec- 
trical  supply should be via a double pole switch having 3 mm. contact  separation  in both  poles. If the  appliance is 
installed in a bathroom  the  fused spur must be external  to  the  bathroom. 
When on pilot  only the  fan  runs at  ‘low speed’ increasing to  normal  speed when there is a demand for  hot  water. 
Included are a pressure switch, which operates  if the fan  stalls or if the  flue  is obstructed,  and a low temperature 
sensor which  will turn  off  the  fan  when the  appliance is running  on pilot  only (fan low speed) in the  event of  low 
air temperatures  likely to cause freezing  in the appliance. 
1.1 
1.2 
Dimensions 
Guarantee 
I 
The guarantee on this appliance is void if  it is not  installed in accordance  with  the  recommendations  made herein 
or in a manner  approved  by the  manufacturer. 
- 
- 