Hardware reference guide
Intelligent/Special Purpose
380
35013379 11/2011
Words per Drop
The following tables shows Words per drop.
Cable Specifications
Specifications for the the three possible Expander Cables are below.
Number of Backplane Expander
modules allowed
1 per backplane
LEDs None.
Required Addressing The Backplane Expander will look like an unfilled slot in
the PLC I/O map.
Power Requirements
Power Consumption 2.5 watts
Bus Current Required 500 mA
Connector 37 pin D-type
Compatibility
Primary Backplane No restrictions
Secondary Backplane All types of Quantum I/O modules can be used in the
secondary backplane, unless otherwise noted in the I/O
documentation.
Programming Software Modsoft V 2.6 or Concept V 2.2 at a minimum
Executive Firmware 140CPUX130X - Version 2.2
140CPUX341X - Version 1.03
140CPUx341xA - Any version
140CPUx341xB - Any version
140CPU42402 - Version 2.15
140CRA93X0X - Version 1.2
Specifications
Maximum words per drop
Local I/O 64 in /64 out
Remote I/O 64 in /64 out
Part Number Length
140 XCA 71703 1 meter
140 XCA 71706 2 meters
140 XCA 71709 3 meters