Specifications
Table Of Contents
- EXPOSURE TO RF RADIATION
- MCC 545B MRC-565 DIFFERENCES
- 1 INTRODUCTION
- 2 NETWORKS
- 3 DESCRIPTION
- 4 INSTALLATION
- 4.1 Cable Connections
- 4.1.1 DC Power
- 4.1.2 VHF Antenna
- 4.1.3 GPS Antenna
- 4.1.4 I/O Port
- 4.1.5 GNSS Ethernet
- 4.1.6 Radio Ethernet Port
- 4.2 Power-Up Sequence
- 4.3 Description of Critical Device Parameters for a LOS Network
- 4.3.1 Device
- 4.3.2 Role
- 4.3.3 Radio ID Number
- 4.3.4 Frequency and Modulation Parameters
- 4.3.5 Select Site Name
- 4.4 Enter Script Files
- 4.5 RF TEST
- 5 OPERATIONS
- 5.1 Getting Started
- 5.1.1 Command Entry and Editing
- 5.1.2 HELP Command
- 5.1.3 System Time and Date
- 5.1.4 Factory Default Parameters
- 5.2 Configuring the MRC-565 Manually
- 5.2.1 Setting the Radio ID
- 5.2.2 Device Type
- 5.2.3 Setting the Operating Role
- 5.2.4 Setting the Power Mode
- 5.2.5 Selecting Network Parameters
- 5.3 Local Area Network Configuration
- 5.3.1 I/O Configuration Commands
- 5.3.2 Scheduling MRC-565 Events
- 5.3.3 Setting Timeout Duration
- 5.3.4 Defining Data Relays
- 5.3.5 Scaling A/D Readings
- 5.3.6 Selecting the Burst Monitor
- 5.3.7 Controlling the Hourly Statistics Report
- 5.3.9 Power Turn On
- 5.3.10 Saving and Restoring the Configuration
- 5.4 Sending and Receiving Messages
- 5.4.1 Entering and Deleting Messages
- 5.4.2 Editing Messages
- 5.4.3 Sending Messages
- 5.4.4 Sending Remote Commands
- 5.4.5 Sending Canned Messages
- 5.4.6 Receiving Messages
- 5.4.7 Examining Message Status
- 5.4.8 Examining and Revising Message Queues
- 5.5 Sensor I/O Port
- 5.6 Data Loggers Interface
- 5.7 CR10X Data Logger
- 5.7.5 Update Interval
- 5.7.6 Transmission Order
- 5.7.8 Time of Day
- 5.7.9 Time Tagging
- 5.7.10 Memory Management
- 5.7.11 Data Scaling
- 5.7.12 Modem Enable
- 5.7.13 Setting/Reading CR10X Internal Registers
- 5.7.14 Entering CR10X Security Codes
- 5.7.15 Downloading a CR10X .DLD Program
- 5.7.16 Replacing an MRC-565 to an Operational CR10X
- 5.7.17 Replaying Data from a CR10X
- 5.8 CR1000 Data Logger
- 5.8.1 CR1000 Driver Configuration Command Summary:
- 5.8.2 Acquire Mode:
- 5.8.3 Data Retrieval Pointer Initialization
- 5.8.4 Data Retrieval Hole Collection
- 5.8.5 Update Interval
- 5.8.6 Transmission Order
- 5.8.7 Group ID Assignment
- 5.8.8 Time of Day
- 5.8.9 Time Tagging
- 5.8.10 Memory Management
- 5.8.11 Data Scaling
- 5.8.12 Modem Enable
- 5.8.13 Reading CR1000 Internal Pointers and Error Statistics
- 5.8.14 Displaying Status Table Data
- 5.8.15 Displaying and Setting Public Table Data
- 5.8.16 Downloading a Program
- 5.9 SDI-12 Sensors
- 5.9.1 Data Collection
- 5.9.2 Setup
- 5.9.3 Periodic Data Collection
- 5.9.4 Data Logging
- 5.9.5 User Interface
- 5.9.6 MRC-565 Commands
- 5.9.7 SDI, CMD, COMMAND TEXT
- 5.9.8 SDI, TRACE, {OFF/ON}
- 5.9.9 SDI-12 Command/Response List
- 5.9.10 Serial Port Command and Response Diagrams
- 5.10 Generic Data Logger
- 5.10.1 Typical Report Formats
- 5.10.2 Setup and Configuration
- 5.10.3 Viewing the generic device driver setup
- 5.10.4 AUTO Format
- 5.10.5 MULTI-LINE Format
- 5.11 Event Programming
- 6 THEORY OF OPERATION
- 6.1 CMU (MRC-56500300-04)
- 6.1.1 Receiver Analog Front End
- 6.1.2 Digital Receiver Components
- 6.1.3 Digital Transmitter Components
- 6.1.4 Discrete Digital Output, Relay Junction and Analog Input
- 6.1.5 Power Amp Interface
- 6.2 Microprocessor
- 6.2.1 Overview
- 6.2.2 Cold Fire Processor
- 6.2.3 Data Input/Output
- 6.2.4 Coldfire Microprocessor Peripherals and Serial Configuration
- 6.2.5 Power Fail Detection/Protection
- 6.2.6 Voltage Regulators
- 6.2.6.1 Input Switching Regulator
- 6.2.6.2 CF Switching Regulator
- A three output switching regulator is used to generate the three voltages that power the Cold Fire Processor and its peripheral devices. The three voltage are:
- 3.3V Powers CF54455 I/O, CPLD, RS232 interfaces, Flash Memory, Ethernet Controller
- 6.2.6.3 DSP Switching Regulator
- A three output switching regulator is used to generate the three voltages that power all circuitry associated with the Receiver and Exciter circuitry. The three voltages are:
- 3.6V Powers FPGA and DSP I/O, Rx Clock synthesizer, RF Pre Amps, TCXO, and QDUC circuit.
- 2.0V Powers the ADC circuit, the FPGA Core (1.2V), and the DSP Core (1.6V)
- 6.2.6.4 5 V Regulator
- 6.3 Power Amplifier (MRC-56500301-10)
- 6.4 Internal GNSS daughter board (optional)
- 7 Maintenance
- APPENDIX A: COMMANDS
- MESSAGE COMMANDS
- MAINTENANCE COMMANDS
- BOOT
- DATA LOGGER COMMANDS
- CR10X COMMANDS
- COMMAND
- PARAMETERS
- CR10X,GROUP,source
- CR10X,RESET
- CR10X,SCALE,type
- CR10X,SIGNATURE
- CR10X,STAT
- CR10X,TIME,source
- CR1000
- CR1000,ACQMODE,{CURRENT,ALL,LAST,N}
- CR1000,SETPTR,MM/DD/YY,HH:MM
- CR1000,INTERVAL,{off,n}
- CR1000,GROUP,{CR1000}
- CR1000,TIME,{CR1000}
- CR1000,MAXQ,nnn
- CR1000,SCALE,{CR1000,INT}
- CR1000,PUBLIC
- CR10XTD,STAT
- CR10XTD,RESET
- CR10XTD,SECURITY,xxxx,yyyy,zzzz
- CUSTID,nnnnn
- 1 – 4095
- A-Z, 0-9, -
- A-Z, 0-9, -
- A-Z, 0-9, -
- Parameter
- BOOT
- MAINTENANCE COMMANDS
- STATUS COMMANDS
- STATION CONFIGURATION COMMANDS
- APPENDIX B: FACTORY DEFAULTS
- The following is a list of MRC 565 Parameters that are installed after typing:
- To obtain a list of parameters settings in SCRIPT format for the MRC 565 type:
- APPENDIX C: EVENT PROGRAMMING
- APPENDIX D: INSTALLATION DETAILS
OPERATIONS
Page 98 MRC-565 Packet Data Radio Operations & Maintenance
To schedule data collection for our sensors and transmission of the GROUP SDATA report we
could enter the following commands:
SCHED,I,30:0,SDI,COLLECT,1,2
SCHED,I,30:0,OFFSET,15,EVENT,UPDT,1
The first command schedules data collection of sensor table items 1 and 2 every 30 minutes and
00 seconds. The second command schedules the event group 1 to be created and send every 30
seconds with an offset of 15 seconds to give time for the data collection to complete.
5.9.7 SDI, CMD, COMMAND TEXT
Transparent Mode command. This command will output the text to the SDI-12 data line exactly
as typed with the ‘!’ character appended to the end. The first character must be a sensor address
and the remaining characters should be some valid basic or extended SDI-12 Command. The ‘!’
character should not be entered.
Example: SDI,CMD,0V<cr>
A list of the basic SDI-12 commands is given at the end of this document. Some Sensor
Manufacturers have their own special commands for setup and calibration which this transparent
mode is designed to support. These commands are not saved in the radio configuration flash
memory so if the sensor does not retain it in a power cycle it will be lost. If this command is
entered as a real-time-scheduled command it will be saved in the configuration flash memory.
5.9.8 SDI, TRACE, {OFF/ON}
The SDI,TRACE command is useful for debugging the setup and operation of the radio with the
sensors.
The example below shows a data collection from a sensor testing device that was set up to
emulate a sensor. The trace output can get to be a lot of information and should not be left on for
long periods or its output can overrun the radio output memory and cause the radio to reset. Be
careful using this command option.
Characters enclosed in the “<>” characters are transmitted out of the radio. Characters enclosed
in the “[]” characters are received by the radio. The time tag is in hundredths of seconds.
Example with TRACE,ON
+sdi,collect,1
20:14:44.59 <BREAK>
20:14:44.60 <MARK>
20:14:44.62 <0M!>
20:14:44.69 [00056(cr)(lf)]