Specifications

Table Of Contents
OPERATIONS
Page 68 MRC-565 Packet Data Radio Operations & Maintenance
CR10X Display CR10X configuration parameters
,ACQMODE,ALL Get all reports since previous scan
,CURRENT Get only the current (last) data group
,LAST,N Get only the last ‘N’ data groups (backsup ‘N’ data
groups from the last one)
,SETPTR,DATE,TIME Manual set up of last data pointer in
the MRC-565
,INTERVAL,N Scan interval in seconds
,OFF Scan only when UPDT command is entered
,ORDER,FIFO Get final storage data in FIFO order
,LIFO (not avail) Get final storage data in LIFO order
,GROUP,MRC-565A Let MRC-565 assign group numbers
,CR10X Get Group Number from 1
st
stored sensor
,TIME,MRC-565A Use MRC-565 internal Time
,CR10X Get time from 2
nd
and 3
rd
sensor
,MAXQ,NNN Set maximum number of reports to queue
for each scan of the CR10X
,SCALE,CR10X Scale sensors in cr10X Hex units
,INT (or MRC-565A) Scale sensors in integer Hex units
,REGISTER,N Read internal storage register ‘N’
N,DDD Set internal storage register ‘N’ to DDD
,STAT Read and display CR10X internal pointers
and error statistics.
,RESET Reset CR10X internal error statistics.
,SECURITY,1111,2222,3333 Enter CR10X Internal Security Codes
,SIGNATURE Read and Display Current CR10X programs
Signature.
,MODEM ENABLE Enable/Disable use of ME/Ring control
5.7.2 Parameter Default Values
Default values are set up to support systems already deployed in the field. These are defined to
allow only the last single data group to be read each time the UPDT command is entered or
scheduled in the MRC-565. The time tag will use internal MRC-565 date and time, it is assumed
the day and time are not stored in the CR10X data arrays, scaling will be in CR10X Hex format,
transmission in FIFO order, group assignment by the MRC-565 and the maximum queue depth