Specifications
Table Of Contents
- EXPOSURE TO RF RADIATION
- MCC 545B MRC-565 DIFFERENCES
- 1 INTRODUCTION
- 2 NETWORKS
- 3 DESCRIPTION
- 4 INSTALLATION
- 4.1 Cable Connections
- 4.1.1 DC Power
- 4.1.2 VHF Antenna
- 4.1.3 GPS Antenna
- 4.1.4 I/O Port
- 4.1.5 GNSS Ethernet
- 4.1.6 Radio Ethernet Port
- 4.2 Power-Up Sequence
- 4.3 Description of Critical Device Parameters for a LOS Network
- 4.3.1 Device
- 4.3.2 Role
- 4.3.3 Radio ID Number
- 4.3.4 Frequency and Modulation Parameters
- 4.3.5 Select Site Name
- 4.4 Enter Script Files
- 4.5 RF TEST
- 5 OPERATIONS
- 5.1 Getting Started
- 5.1.1 Command Entry and Editing
- 5.1.2 HELP Command
- 5.1.3 System Time and Date
- 5.1.4 Factory Default Parameters
- 5.2 Configuring the MRC-565 Manually
- 5.2.1 Setting the Radio ID
- 5.2.2 Device Type
- 5.2.3 Setting the Operating Role
- 5.2.4 Setting the Power Mode
- 5.2.5 Selecting Network Parameters
- 5.3 Local Area Network Configuration
- 5.3.1 I/O Configuration Commands
- 5.3.2 Scheduling MRC-565 Events
- 5.3.3 Setting Timeout Duration
- 5.3.4 Defining Data Relays
- 5.3.5 Scaling A/D Readings
- 5.3.6 Selecting the Burst Monitor
- 5.3.7 Controlling the Hourly Statistics Report
- 5.3.9 Power Turn On
- 5.3.10 Saving and Restoring the Configuration
- 5.4 Sending and Receiving Messages
- 5.4.1 Entering and Deleting Messages
- 5.4.2 Editing Messages
- 5.4.3 Sending Messages
- 5.4.4 Sending Remote Commands
- 5.4.5 Sending Canned Messages
- 5.4.6 Receiving Messages
- 5.4.7 Examining Message Status
- 5.4.8 Examining and Revising Message Queues
- 5.5 Sensor I/O Port
- 5.6 Data Loggers Interface
- 5.7 CR10X Data Logger
- 5.7.5 Update Interval
- 5.7.6 Transmission Order
- 5.7.8 Time of Day
- 5.7.9 Time Tagging
- 5.7.10 Memory Management
- 5.7.11 Data Scaling
- 5.7.12 Modem Enable
- 5.7.13 Setting/Reading CR10X Internal Registers
- 5.7.14 Entering CR10X Security Codes
- 5.7.15 Downloading a CR10X .DLD Program
- 5.7.16 Replacing an MRC-565 to an Operational CR10X
- 5.7.17 Replaying Data from a CR10X
- 5.8 CR1000 Data Logger
- 5.8.1 CR1000 Driver Configuration Command Summary:
- 5.8.2 Acquire Mode:
- 5.8.3 Data Retrieval Pointer Initialization
- 5.8.4 Data Retrieval Hole Collection
- 5.8.5 Update Interval
- 5.8.6 Transmission Order
- 5.8.7 Group ID Assignment
- 5.8.8 Time of Day
- 5.8.9 Time Tagging
- 5.8.10 Memory Management
- 5.8.11 Data Scaling
- 5.8.12 Modem Enable
- 5.8.13 Reading CR1000 Internal Pointers and Error Statistics
- 5.8.14 Displaying Status Table Data
- 5.8.15 Displaying and Setting Public Table Data
- 5.8.16 Downloading a Program
- 5.9 SDI-12 Sensors
- 5.9.1 Data Collection
- 5.9.2 Setup
- 5.9.3 Periodic Data Collection
- 5.9.4 Data Logging
- 5.9.5 User Interface
- 5.9.6 MRC-565 Commands
- 5.9.7 SDI, CMD, COMMAND TEXT
- 5.9.8 SDI, TRACE, {OFF/ON}
- 5.9.9 SDI-12 Command/Response List
- 5.9.10 Serial Port Command and Response Diagrams
- 5.10 Generic Data Logger
- 5.10.1 Typical Report Formats
- 5.10.2 Setup and Configuration
- 5.10.3 Viewing the generic device driver setup
- 5.10.4 AUTO Format
- 5.10.5 MULTI-LINE Format
- 5.11 Event Programming
- 6 THEORY OF OPERATION
- 6.1 CMU (MRC-56500300-04)
- 6.1.1 Receiver Analog Front End
- 6.1.2 Digital Receiver Components
- 6.1.3 Digital Transmitter Components
- 6.1.4 Discrete Digital Output, Relay Junction and Analog Input
- 6.1.5 Power Amp Interface
- 6.2 Microprocessor
- 6.2.1 Overview
- 6.2.2 Cold Fire Processor
- 6.2.3 Data Input/Output
- 6.2.4 Coldfire Microprocessor Peripherals and Serial Configuration
- 6.2.5 Power Fail Detection/Protection
- 6.2.6 Voltage Regulators
- 6.2.6.1 Input Switching Regulator
- 6.2.6.2 CF Switching Regulator
- A three output switching regulator is used to generate the three voltages that power the Cold Fire Processor and its peripheral devices. The three voltage are:
- 3.3V Powers CF54455 I/O, CPLD, RS232 interfaces, Flash Memory, Ethernet Controller
- 6.2.6.3 DSP Switching Regulator
- A three output switching regulator is used to generate the three voltages that power all circuitry associated with the Receiver and Exciter circuitry. The three voltages are:
- 3.6V Powers FPGA and DSP I/O, Rx Clock synthesizer, RF Pre Amps, TCXO, and QDUC circuit.
- 2.0V Powers the ADC circuit, the FPGA Core (1.2V), and the DSP Core (1.6V)
- 6.2.6.4 5 V Regulator
- 6.3 Power Amplifier (MRC-56500301-10)
- 6.4 Internal GNSS daughter board (optional)
- 7 Maintenance
- APPENDIX A: COMMANDS
- MESSAGE COMMANDS
- MAINTENANCE COMMANDS
- BOOT
- DATA LOGGER COMMANDS
- CR10X COMMANDS
- COMMAND
- PARAMETERS
- CR10X,GROUP,source
- CR10X,RESET
- CR10X,SCALE,type
- CR10X,SIGNATURE
- CR10X,STAT
- CR10X,TIME,source
- CR1000
- CR1000,ACQMODE,{CURRENT,ALL,LAST,N}
- CR1000,SETPTR,MM/DD/YY,HH:MM
- CR1000,INTERVAL,{off,n}
- CR1000,GROUP,{CR1000}
- CR1000,TIME,{CR1000}
- CR1000,MAXQ,nnn
- CR1000,SCALE,{CR1000,INT}
- CR1000,PUBLIC
- CR10XTD,STAT
- CR10XTD,RESET
- CR10XTD,SECURITY,xxxx,yyyy,zzzz
- CUSTID,nnnnn
- 1 – 4095
- A-Z, 0-9, -
- A-Z, 0-9, -
- A-Z, 0-9, -
- Parameter
- BOOT
- MAINTENANCE COMMANDS
- STATUS COMMANDS
- STATION CONFIGURATION COMMANDS
- APPENDIX B: FACTORY DEFAULTS
- The following is a list of MRC 565 Parameters that are installed after typing:
- To obtain a list of parameters settings in SCRIPT format for the MRC 565 type:
- APPENDIX C: EVENT PROGRAMMING
- APPENDIX D: INSTALLATION DETAILS
OPERATIONS
Page 52 MRC-565 Packet Data Radio Operations & Maintenance
timeout the time limits may be set by entering the number of seconds, from 0 to 32767. Enter a 0
to turn off the time limit.
Command Description
STT,secs The Set Teleprinter Timeout command sets the time limit for characters at the
maintenance terminal. Default is 60 seconds (1 minute).
5.3.4 Defining Data Relays
The ambient noise conditions at a remote station site may sometimes be excessive and a poor
communication path to the Master Station will result particularly if the remote station is
operating in a meteor burst mode. To overcome this problem, another MRC-565 may be placed
in a nearby quiet location and used as relay station between the MRC-565 at the noisy site and its
master station. When used as a relay, the MRC-565 will concentrate the data reports it receives
from one or more neighboring remote sites and forwards the data to the Master Station.
In this mode, the MRC-565 must be defined as a Master Station. The relay will then receive
Group data reports from other MRC-565 units located in noisy or un secure locations and
repackage them and forward them to the Master Station. A relay can handle sixteen GROUP
reports. These reports can be in any combination; i.e., four groups from each of four Remote
units, one group from each of sixteen Remote units or any combination in between. Substitution
tables must be established in both the relay unit and at the Master Station to manage the relay
function.
When a designated GROUP report is received at the relay, it will substitute its own ID and group
number in the report as defined in its substitution table and forward the data to an MRC-520B
Master Station using the MRC-550C RF format rather than the standard MRC-565 message
format. When the relayed data is received at the MRC-520B it reconstructs the original data
report based on its own substitution table and route the report as required.
The following command is used to define the entries in the substitution table for a relay unit:
SUBST,relay_id,relay_group,remote_id,remote_group
where: relay_id is the relay unit's ID
relay_group is the data group report number at the relay
remote_id is the originating Remote unit's ID
remote_group is the data group report number at the originating Remote unit
5.3.5 Scaling A/D Readings
The MRC-565 contain a 12 bit A/D converter that is used to measure 16 analog voltages input
including: