Specifications

Table Of Contents
INSTALLATION
Page 34 MRC-565 Packet Data Radio Operations and Maintenance
With the exception of the CPLD, all versions of software can be updated via the Operator Port.
The CPLD requires direct connection of the Altera Blaster to the board.
4.3 Description of Critical Device Parameters for a LOS Network
Most of the parameters used in a MB network do not have to be changed from there Factory
Defaults for normal operation. However, a few critical parameters must be set to obtain proper
operations. These are described below. These commands should be included in the SCRIPT
file used to program the unit as described in Section 4,4 below.
4.3.1 Device
The MRC-565 can be programmed to operate as a REMOTE or BASE. To check the Device
Type enter the following command:
DEVICE [ENTER]
If the device is not a REMOTE and you want to change it to a REMOTE enter
DEVICE,REMOTE [ENTER]
SAVE [ENTER] SAVE stores the Device type into FLASH memory.
If you want to operate as a Base enter
DEVICE,BASE [ENTER]
SAVE [ENTER]
4.3.2 Role
ROLE is used to set the Operating Mode and the RF Protocol for the device.
LOS Used LOS networks
To determine the operating ROLE for the device, type the following command:
ROLE [ENTER}