Page 33 MRC-565 Packet Data Radio Operations and Maintenance
4.2 Power-Up Sequence
Connect a laptop, with XTERMW installed, to the Operator Port (MNT). The Operator Port
settings of the MRC-565 is programmed with the following factory default configuration at the
time of shipment:
Baud rate 9600
Data bits 8
Stop bit 1
Parity no
Protocol ASCII
Flow control none
When the unit first turns on after applying power the PWR, RX1, RX2, and RX3 front panel
LED's will turn on for about 2 seconds. This indicates that +12V is applied to the unit and that
the internal 3.3V regulators have turned on. At this point, the main control software is booting
up. After a few more seconds, the PWR LED will start flashing and the other LED's should turn
off. This flashing indicates that the main control software is running and the following messages
should be printed on the operator (MNT) port.
03/20/14 08:00:50 MNT port 0
/
/ / /
/ / /
*** O / O Maiden Rock Comm, LLC
******* O /\
/\ ********* /\/ \/\
/\/ ***********\/ \ / \
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
MRC-565 Packet Data Radio
Copyright (C) 2014 Maiden Rock Comm, LLC
All Rights Reserved
CMU Version 1.01.0121 10/15/21 07:30 AM
DSP Version 02.10 140221a_fc
FPGA Version 01.20 140216_ab
CPLD Version 56 01/27/14a
The software versions numbers for the CMU (Coldfire processor), DSP, FPGA, and the CPLD
are displayed. These numbers will change as newer versions of the software are developed. The
CPLD is an Altera Complex Programmable Logic Device. It is a single chip device used to
interface the various I/O functions with the Cold Fire Processor. The CPLD version must be 56
or the PA power level control commands will not function properly