Specifications

Table Of Contents
INSTALLATION
Page 32 MRC-565 Packet Data Radio Operations and Maintenance
19
Analog Input #3 ( 0 to 5 V) ±1%
20
Analog Input #4 ( 0 to 5 V) ±1%
21
Analog Input #5 ( 0 to 5 V) ±1%
22
Analog Input #6 ( 0 to 5 V) ±1%
23
+12V Switched (.5A Max)
24
+12V (0.5A Max)
25
Det RF for Chan #1
4.1.5 GNSS Ethernet
GNSS Ethernet Port on the front panel of the MRC565 Radio is used to configure and monitor
the internal GNSS daughter board attached to the Main CMU board. To access, a web browser
the default IP address 192.168.10.2 port 80 can be used.
4.1.6 Radio Ethernet Port
Ethernet Port that supports TCP/IP protocol is used to connect the MRC-565 to a wired Wide
Area Network (WAN). This eliminates the need for a router and terminal server to route data
back to a Host Computer.
There are two commands required to set up the Ethernet Port for operation. Enter the following
command to check the configuration:
IPCONFIG
The Ethernet port factory defaults to an IP address of
192.168.10.1
To change the IP address enter the following command
IPCONFIG,E1,nnn.mmm.ppp,qqq E1 is the Ethernet port.
To enable the port use the following command:
ASSIG,function1,n,protocol
where E1F1 is the function, n is the port number, and p is the protocl
The function can be ASCII,MSC,or MSC2
The port can be 4,5,6,or 7
A complete description of the TCP/IP protocol is given in Section 5.3.1.2 .