Specifications

Table Of Contents
APPENDIX A: COMMANDS
Page 166 MRC-565 Packet Data Radio Operations & Maintenance
MRC-565 COMMANDS
TABLE
COMMAND
DESCRIPTION
PARAMETERS
RANGE
and REMCMD), or any
commands that change port
configurations.
SCHED,DEL,nn
Delete specified schedule item number. If nn =
ALL, the entire schedule will be cleared.
nn = schedule item
number
1 – 50
SDATA,g,c,time stamp,
value...
Enter an MCC-550C data report directly from the
serial I/O port. Up to 16 values may be entered. Use
the LINK command to route the data. Enter
00000000 in Time Stamp to use current time.
g = group number
c = sensor count
time stamp = mdddhhmn
value = ASCII hex sensor
value
1 – 4
1 – 16
mm 1 – 12
dd 1 – 31
hh 0 – 23
mn 0 – 59
0 – FFFF
SERIAL{,sss}
Set next packet serial number. Parameter “sss” is
serial number of last packet transmitted.
sss = message serial
number
1 – 255
SERIALNUMBER{,sn}
Display/Set serial number of this modem
*SET BAUD
{,function,baud,parity,data,stop
,flow}
Adjust baud rate and flow control of specified port.
When no parameters are entered, this command
displays I/O configurations.
function = user interface
function
baud = baud rate
parity
data
stop
flow = flow control
ALT,C&S,DT
A,MNT,MSG,
POS
50-115200
O/E/N
5/6/7/8
1/2
Y or N