Specifications

Table Of Contents
APPENDIX A: COMMANDS
Page 165 MRC-565 Packet Data Radio Operations & Maintenance
MRC-565 COMMANDS
TABLE
COMMAND
DESCRIPTION
PARAMETERS
RANGE
ADC6 1.0000000 0.0000 0.0000000 0.0000000
+
SCALE,parameter,value{,offs
et}
Display set A/D scaling factors for the unit. Factors
depend on type of receiver and power supply used in
the MCC-6100.
parameter =
VBATbattery
voltage
PA_VFPA Fwd Pwr
PA_VRPA Rev Pwr
PA_TEMP- PA Temp
3.3V
1.8V
1.5VCFC
3.3VDSP
1.6VDSPC
1.2VFPGAC
ADC1, . . . ADC6
value = scale factor
SCHED
Display all scheduled commands
SCHED{,basis,hh:mm:ss
{,OFFSET,hh:mm:ss},
command string}
IMPORTANT
Up to 50 commands can be
scheduled. Do not schedule
commands that require user
interaction (such MESSAGE
Schedule execution of the specified command string.
If timeframe basis = INTERVAL, the command
string will be executed whenever the specified time
interval elapses during the day. If timeframe basis =
TIME, the command string will be executed at the
specified time. The OFFSET option allows
specification of an offset from the timeframe basis.
basis = TIME or
INTERVAL
hh - hours
mm - minutes
ss - seconds
0 – 23
0 – 59
0 – 59