Page 153 MRC-565 Packet Data Radio Operations & Maintenance
MRC-565 COMMANDS
TABLE
COMMAND
DESCRIPTION
PARAMETERS
RANGE
probe
OFF = ignore host
connection state; keep
transmitting and do
not set bit flagging
loss in probe
HOSTSEGFWD{,on,off}
Enable/Disable multi-Master segment mode.
*HOURLIES{,action}
Turn on/off hourly statistics.
action =
ON – enable
OFF – disable
HTTL{,n}
Set Host port timeout in minutes.
If device = Remote: Normal
operation
*ID{,nnn,mmm{,mode}
{,INIT}}
NOTE
Remote and Master IDs are
kept in CPM, and mode is kept
in RAM.
Set MRC 525’s assigned Master Station ID to
number “nnn”. When no parameters are given,
current ID is displayed. When system is already
initialized, you must enter the INIT parameter to
change ID. INIT gives “OK” to save configuration
and reboot unit with new ID. ID changes are
automatically saved with the entire configuration in
CPM. “mode” parameter (if used) specifies initial
connectivity with specified Master. AUTO means
no connectivity established. PREF means Remote
considers connectivity established. FIXED (Default)
means connect only with specified Master. MULTI
means Remote can connect to multiple Master
Stations.
NOTE
If command does not change the ID or Master
Station, the SAVE and reboot are not performed.
nnn = Remote ID
mmm = Master ID
mode mode = AUTO,
PREF, FIXED, or
MULTI
INIT = initializes ID
change
256 – 4095
1 – 245