Specifications

Table Of Contents
APPENDIX A: COMMANDS
Page 150 MRC-565 Packet Data Radio Operations & Maintenance
MRC-565 COMMANDS
TABLE
COMMAND
DESCRIPTION
PARAMETERS
RANGE
O
number 1 and increment by 1 for each 16 sensor
values.
GENERIC,Port,GROUP,LIN
E,1stGrpNo,START,END
The LINE option allows the group number to be
within the data at the given line number and between
the given start and end column numbers.
GENERIC,Port,GROUP,FIX
ED,GrpNo
The FIXED option will use the Line Number
parameter as the first group number then increment
by 1 for each 16 sensor values.
GENERIC,Port,GROUP,SCA
LE,{FLOAT,INT}
The SCALE option will scale sensor values by the
factor given. (Default scale is “1”.)
GENERIC,Port,DATE,AUTO
The AUTO date option will use the MCC-6100
internal Date.
GENERIC,Port,DATE,LINE,
LineNo,START,END{,MM/D
D/YY}
The LINE option allows the date to be within the
data at the given line number and between the given
start and end column numbers.
The FORMAT is
optional, and shows a
“template” of the date
format. It can be
“MM/DD/YY”,
“YY/MM/DD”,
“MMDDYY”,
“YYMMDD”. If the
format is not given it
will default to the
“MM/DD/YY” format.
GENERIC,Port,TIME,AUTO
The AUTO time option will use the MCC-6100
internal time.
GENERIC,Port,TIME,LINE,L
ineNo,START,END,{,HH:MM
:SS}
The LINE option allows the time to be within the
data at the given line number and between the given
start and end column numbers.
The FORMAT is
optional, and shows a
“template” of the time