Specifications

Table Of Contents
APPENDIX A: COMMANDS
Page 139 MRC-565 Packet Data Radio Operations & Maintenance
MRC-565 COMMANDS
TABLE
COMMAND
DESCRIPTION
PARAMETERS
RANGE
pattern
CR10X
Display CR10X configuration parameters
CR10X,ACQMODE,mode
Set CR10X acquisition mode - Get all reports since
last UPDT
mode =
ALLget all reports
since last update
CURRENT – get
only the current data
report
LAST,n – get last “n”
data reports
CR10X,GROUP,source
Specify source of data report group assignment.
source =
565 – 565 assigns
group numbers;
CR10X internal group
number matches data
array
CR10XCR10X
assigns group
numbers; 565 gets
group number from
first sensor
CR10X,INTERVAL,n
Acquisition scan interval in seconds. OFF disables
acquisition scan
n = seconds
0 – 32767
CR10X,MAXQ,nnn
Set maximum number of reports to queue for each
scan of the CR10X
nnn = number of
reports
1 – 200
CR10X,REGISTER,n{,ddd}
Read/Set internal storage register.
n = register number
ddd = value
1 – 28
Signed floating
point number
(see CR10X
manual)