Page 130 MRC-565 Packet Data Radio Operations & Maintenance
Once you enter the Cal parameters noted above, you should save these values, so that when the
SW reboots or power is removed from the MRC 525, the parameters are saved. To SAVE Cal
parameters enter the following commands:
CALRAND to obtain a CALRAND#
CAL,SAVE,CALRAND# to save the values
Once you have saved these parameters, enter the following command to display the cal
parameters.
CAL
Record the results.
7.3.2 Power Amp Adjustments
The MRC-56500301-10 Power Amplifier is factory tuned to the customer specific frequencies at
the factory. These parameters should not be changed in the field. With the 56500301-10 FET
PA Amplifier 4 different power levels can be selected using the RFP command. RFP,10 10
Watts, RFP,25 25 watt, RFP,50 50 watts and RFP,100 100 watts.