User Manual

RTI Technologies, Inc.
September 30, 1999 Page 9
9
0
F
R12 R134a
30 42 40
32 44 42
34 46 44
36 48 46
38 50 49
40 52 51
42 54 54
44 57 56
46 59 59
48 61 61
50 64 64
52 66 67
54 69 70
56 72 72
58 74 76
60 77 78
62 80 82
64 83 85
66 85 88
68 88 92
70 92 95
72 95 97
74 98 104
76 102 107
78 105 110
80 108 114
82 112 118
84 115 123
86 118 127
88 123 130
90 127 135
92 130 140
94 135 145
96 138 148
98 143 153
100 147 157
102 150 163
104 155 167
106 160 173
108 165 180
110 168 185
112 173 190
114 178 195
116 183 200
118 188 207
Purge Chart
OIL DRAIN & AIR PURGE
Oil and Non-condensable Gas (Air) are separated from the
recovered refrigerant and MUST be removed following
EACH recycling procedure as follows:
Note: TC2670 must be connected to power source.
1. Press and hold the Purge Button (below the Purge
Gauge) for 5 seconds, and then release it.
2. SLOWLY open the Oil Drain Valve (located on rear of
TC2670 towards outside) to drain any oil which may
have been removed from the A/C System. A cup is
provided to collect the oil.
Unless the A/C System had previously been overfilled,
the TC2670 will typically not remove more than a
tablespoon of oil, making replenishment unnecessary.
LEAVE THE OIL DRAIN VALVE OPEN...
3. Determine the room temperature.
4. Locate the pressure (PSIG) corresponding to this room
temperature (
0
F) in the chart on the top of the
TC2670. This chart is reproduced at the right.
If the pressure indicated on the Purge Gauge is greater
than that determined from the chart:
Press and hold the Purge Button until the Purge Gauge
pressure goes down to the pressure determined from
the chart. Any Non-condensable Gas will be vented
through the Oil Drain Valve at this time.
5. Close the Oil Drain Valve.
6. Press and hold the Purge Button for 5 seconds. This
permits any residual Non-condensable Gas to be
recirculated for reprocessing during the next recycle
procedure.