Specifications
C:\RHS Computer Files\Instructions\RHS\GB\642-40\0012B-01.doc 1997.09.11
RHS 900
General:
Supply voltage: See nameplate
Amperage: See nameplate
Power consumption: See nameplate
Starting current: See nameplate
Weight: 95 kg
Dimensions: 1030 x 670 x 800 mm
Test function:
High-pressure gauge: 0 to 34 bar
Low-pressure gauge: -1 to 8 bar
Recovery/recycling process:
Refrigerant: See nameplate
Oil level measurement: Drain at side of station, measuring beaker
supplied
Recycling capacity: 4 kg/h (3-5 vehicles/h)
Non-condensable gases: Automatic blow-off, temperature-compensated
Suctionaccumolator: 2,4 L.
Charging capacity: 7 Kg. Optional 14 Kg.
Charging accuracy: ±2% with 40 cm. hoses.
Dryer: Exchangeable (after 75 operating houers)
Evacuation process:
Suction capacity: Approx. 3 m
3
/h
Vacuum level: < 0.5 mbar absolute
Oil charging: Oil reservoir : 250 ml