User Manual

Page 5
RECOVERY / RECYCLING
Select the RECOVERY/RECYCLING process to drain refrigerant from the A/C system prior to repair
or service.
1. Make sure that all valves are closed, then connect high and low pressure hoses to the A/C
system and open the service hose valves.
2. Set the process selector to RECOVERY/RECYCLING and turn on main switch.
3. Open valves 1 and 2. If there is refrigerant pressure in the A/C system, the RHS650 will
automatically recover it. The white lamp RECOVERY/RECYCLING lights up until the process
is complete.
4. When the white lamp goes out for the first time, wait 5 minutes in order to ensure that the A/C
system is completely empty.