Owner`s manual
Table Of Contents
- Page 1
- Page 2
- Page 3
- Page 4
- Page 5
- Page 6
- Page 7
- Page 8
- Page 9
- Page 10
- Page 11
- Page 12
- Page 13
- Page 14
- Page 15
- Page 16
- Page 17
- Page 18
- Page 19
- Page 20
- Page 21
- Page 22
- Page 23
- Page 24
- Page 25
- Page 26
- Page 27
- Page 28
- Page 29
- Page 30
- Page 31
- Page 32
- Page 33
- Page 34
- Page 35
- Page 36
- Page 37
- Page 38
- Page 39
- Page 40
- Page 41
- Page 42
- Page 43
- Page 44
- Page 45
- Page 46
- Page 47
- Page 48
- Page 49
- Page 50
- Page 51
- Page 52
- Page 53
- Page 54
- Page 55
- Page 56
- Page 57
- Page 58
- Page 59
- Page 60
- Page 61
- Page 62
- Page 63
- Page 64
- Page 65
- Page 66
- Page 67
- Page 68
- Page 69
- Page 70
- Page 71
- Page 72
- Page 73
- Page 74
- Page 75
- Page 76
- Page 77
- Page 78
- Page 79
- Page 80
- Page 81
- Page 82
- Page 83
- Page 84
- Page 85
- Page 86
- Page 87
- Page 88
- Page 89
- Page 90
- Page 91
- Page 92
- Page 93
- Page 94
- Page 95
- Page 96
- Page 97
- Page 98
- Page 99
- Page 100
- Page 101
- Page 102
- Page 103
- Page 104
- Page 105
- Page 106
- Page 107
- Page 108
- Page 109
- Page 110
- Page 111
- Page 112
- Page 113
- Page 114

3.11 CHARGING TROUBLESHOOTING
I. Charge Light does not come
on when car is put on charge and
‘INSERT PLUG FULL’ message.
II. Temperature Light is on while
charging.
iii. Car does not charge with ‘CHARGE
FAULT’ message on cluster.
RCD:
I. OK LED not ON
II. Fault LED ON
III. RESET Button tripped
PROBLEM
,
There may not be power supply at
External Power Source.
,
Charging Cable may not be properly
connected to Power Source or not
inserted properly to Charge Port.
,
Charging time of car may
increase due to high battery /
charger or ambient temperature.
,
May be problem in charging system.
,
Power supply interrupted, may not
be switched on or earthing is not
OK.
,
Power supply voltage is low or high.
,
High leakage current at charge plug.
,
Earth leakage current is high
,
Power Supply needs to be restored /
ensured.
,
Re-insert charging cable to Power Source
and / or push handle fully on to Charge
base Plate and observe on cluster
message ‘Insert plug full’ goes off.
,
Check for cooling fan noise and charge in
shade/cooler temperature or during
night when ambient temperature is low.
,
Contact dealer for assistance.
,
Restore power supply / switch on power
or get earth of point rectified.
,
Get supply voltage corrected.
,
Get plug point wiring rectified.
(Reset RCD and check)
,
Get earth circuit rectified.
POSSIBLE CAUSE REMEDY
Charging
28
Charging
29
M C B
NOTE
Charge Point Specification:
Power requirement: 3KW, Single phase
Plug Socket: 15Amps SP 220V
Wire thickness: 4sq mm for 25 meters, 6sq mm up to 100 meters length
SAFETY: The power source should have MCB & proper earthing.
3.12 CHARGING POINT REQUIREMENTS
DISTRIBUTION
BOARD
NEUTRAL
EARTHING
PHASE
MCB