Specifications

19
SECTION 4. TROUBLESHOOTING GUIDE
REQUIREMENTS
Personal Computer.
USB Interface Cable, Part Number: 22350300
AC adapter, Part Number: 64300090 (U.S) or 64300080 (International)
Sample checks, Part Number: 96530005.
SET-UP
1. Plug USB cable into the ImageSafe Scanner.
2. Plug the other end of the USB cable into the PC.
3. Power on the ImageSafe Scanner.
4. Start trouble-shooting procedure at Step 00.
TROUBLESHOOTING
00 Check LED
Check the status of the LED indicator:
Off, continue to step 01.
Green, continue to step 02.
Blinking red, continue to step 07.
Red, continue to step 12.
01 Check the Power to the ImageSafe Scanner
Possible causes for this problem are:
AC adapter connection to outlet - make sure the AC adapter is securely connected to outlet
on the wall or power strip.
AC adapter connection to ImageSafe Scanner - make sure the AC adapter is securely
connected to the power jack on the Cable.
Power strip - if using a power strip, make sure the strip is connected to outlet on the wall and
the switch on the strip is turned on.
AC adapter is defective - replace the AC adapter.
Determine if any of the conditions described above are true:
If yes, rectify and continue to step 00.
If no, continue to step 12.
02 Read a check
Read a check through the ImageSafe Scanner:
If the check is transported all the way around the check path, continue to step 03.