Specifications

4 - Configuration
DynaPro| Secure Cryptographic Device for PIN and Data Entry | Installation and Operation Manual
Page 25 of 40 (D99875586-41)
4 Configuration
The device has many commands the host software can use to change and monitor its behavior. They are
documented in detail in D99875585 DYNAPRO PROGRAMMER'S MANUAL (COMMANDS).
In addition, when the device is on the Welcome page or showing an error message, operators can view
or change some configuration options using the keypad and display. Table 4-1 lists these features.
Table 4-1 - Keypad Configuration Features
Operation
Key Sequence
Notes
Change display
brightness
Left Function Key
5 2 3
Right Function Key
See section 4.1 How to Configure the Display
Brightness.
Change network
configuration
Left Function Key
2 4 7
Right Function Key
See section 4.2 How to Configure Ethernet Settings.
Show EMV details
Left Function Key
7 8 3
Right Function Key
Displays a page showing information about the EMV
functions of the device.
Show network
configuration
Left Function Key
2 4 8
Right Function Key
Displays a page showing the device’s network
configuration.
Show MAC address
Left Function Key
6 2 2
Right Function Key
Displays a page showing the device’s MAC address.
Show IP address
Left Function Key
4 7 2
Right Function Key
Displays a page showing the device’s current IP
address.
Show Ethernet
firmware number
Left Function Key
3 9 8
Right Function Key
Displays a page showing the device’s Ethernet module
firmware part number and revision number.