NOTES
.;
If possible install an interior chimney as it will provide better performance. In areas with continuous
temperatures below 18 C (0 F), the use of an exterior chimney increases the likelihood
of
operating problems
such as low draft. high rate
of
crcosoting, and poor startup cha racteristics. Exterior chimneys arc also prone
to down drafting and flow reversal. Installations which arc located low in the house such as in a basement, in
combination with outside chimneys, arc especially prone 10 flow reversal.
.;
A chimney venting a
fi
replace shall not vent anyother appliance.
.;
The MAG NUM
ZC
fireplace is not listed for usc with a masonry chimney or with chimney lin
er
.
.;
The minimum chimney height. including fireplace, is 12' 6" (3.8 Ill) for vertical chimney.
./' Chimney - Any listed type l iT 7" or S" diameter 2 100 degree insulated or air-cooled.
./'
'111C maximum chimney height supported by the fireplace is 10' (3 m). If add itional height is required, usc a
roof support at 3
0'
(9 m) interval.
./' The chimney must extend at least 3' (9 15 mm) above its point
of
contact with the roof and at least 2' (610
111
1ll) hig
hcr
than any wall, roof or building with in 10' (3000 mm)
of
it
(SEE
FIGURE IS).
./' If the chimney extends higher than 5' (1500 mm) above the ro
of
, it must be secured using a roof brace or
guide wires.
./' A rain cap must be installed on top of the chimney. Failure 10 install a rain cap may cause the fireplace to
corrode.
Th
c w
arran
ty will be void if a
ra
in ca p is
1I
011lscd.
,/
Cut and frame square holes in all floors and the roof to provide 2" (SOmm)
of
clearance between the chimney
and any combustible material. Do not fill this
2"
(50 mm) space with any mate rial.
./' Portions
of
Ihe chimney may extend through accessible spaces and shall be enclosed in all
ca
ses to avoid
personal contact with the chimney and damage to the chimney.