User Manual

IVx3 Injection Valve Manual
Rev. 03/2012 Page | 17
Connections:
Stand-Alone Injection Valve When used as a stand-alone injection valve it, can be
remotely controlled. To put the IVX3 into Injection mode send a constant 6 bar (90psi)
air signal to the Injection Signal port. Remove the air signal and the valve will return to
the Off mode. To put the IVX3 into Purge mode send a constant 6 bar (90psi) air signal
to the Purge signal port. Again remove the air signal and the valve will return to the Off
mode.
Valve Pressure Ratings:
Actuator air pressure: 6 bar (87 PSI) 7 bar (102 PSI).
Maximum fluid pressure (resin ports): 7 bar (102 PSI).
NOTE: Use clean filtered non-lubricated air to supply the signal ports of the
actuator.
Purge signal port
Inject signal port
Resin / Solvent Inlet
Resin / Solvent Outlet
Resin Injection Port