User Manual

IVx3 Injection Valve Manual
Rev. 03/2012 Page | 16
Overview:
IVX3 Valve Mode Overview:
OFF Mode this is the default mode the injection, purge and input ports are blocked.
Closed - no fluid can move through the valve.
Injection Mode by applying an air signal to the Injection signal port the valve will open
allowing material into the mold through the Universal insert port.
Purge Mode by applying an air signal to the Purge signal port the valve will allow
resin or solvent through to the Purge port.
Resin / Purge Input Hose with QD connector
Purge Outlet Hose
Universal Insert / Injection Port
Fluid Valve assembly
Inject signal port
Purge signal port