Manual
INSTALLATION AND OPERATIONS MANUAL CB-8000-XXX
MAGNUM VENUS PLASTECH REV 1.05
APRIL 2013 PAGE 18
Press the SEL key COUNTER A SCALE FACTOR Display will read CntA ScF.
Scale Factor entry.
At this point you will have the option to set
the scale factor for calibration. Press the
RST key if you wish to set the scale factor.
Press the RST key to adjust the number and
use the SEL key to move from
number to number.
Once you have set the scale factor, press
and hold the SEL key to accept the number.
Press the SEL key. COUNTER A RESET ACTION Display will read CntA-rST. Default setting
should be to ZEro.
Press the SEL key. COUNTER A COUNT DIRECTION Display will read CntA-dir. Default setting
should be NOr.
Press the SEL key. COUNTER A COUNT LOAD VALUE Display will read CntA-Ld. Default setting
should be 50.00. This setting has no
bearing on this programming.
Press the SEL key. COUNTER B BATCH COUNT ENABLE Display will read CntB-bAt. Default setting
should be NO.
Press the SEL key. COUNTER RESET AT POWER-UP Display will read RST P-UP. Default setting
should be NO.
Press the SEL key. USER INPUT FUNCTION Display will read User-INP. Default setting
should be rESET.
*** Note: MVP recommends no more than 2 decimal points be used.