Manual
INSTALLATION AND OPERATIONS MANUAL CB-8000-XXX
MAGNUM VENUS PLASTECH REV 1.05
APRIL 2013 PAGE 16
Press the PAR key.*** COUNTER A SCALE FACTOR Display will read A-ScF.
Scale Factor entry.
At this point you will have the option to set
the scale factor for calibration. Press the
SEL key if you wish to set the scale factor.
Press the SEL key to adjust the number and
use the RST key to move from number to
number. Please see Chapter 5-Calibration
section for setting this number.
Press the PAR key. COUNTER A RESET ACTION Display will read A-rST. Default setting
should be ZEro.
Press the PAR key. COUNTER A COUNT DIRECTION Display will read A-dir. Default setting
should be NOr.
Press the PAR key. COUNTER A COUNT LOAD VALUE Display will read Cnt-Ld. Default setting
should be 50.00. This setting has no
bearing on this programming.
Press the PAR key. COUNTER B BATCH COUNT ENABLE Display will read b-bAt. Default setting
should be NO.
Press the PAR key. COUNTER RESET AT POWER-UP Display will read r P-UP. Default setting
should be NO.
Press the PAR key. USER INPUT FUNCTION Display will read Usr-INP. Default setting
should be rESET.
Press the PAR key. Display will read Pro or No.
Press the PAR key. This will exit programming mode.
*** Note: MVP recommends no more than 2 decimal points be used.