Owner manual
Advantage Gelcoater
Figure 38: Remove Filter Tank
Clean the filter tank, spring, screen and filter core in solvent.
Reassemble accumulator and filter assembly.
Unlock the gun trigger.
Push flush button located on side of gun to flush gun block.
Shutdown Flush System
Turn the FLUSH regulator knob on the manifold until the gauge reads “0”.
Close air supply valve to the flush system.
Relieve the pressure in the solvent tank by gently pulling up on the pres-
sure relief valve lever.
Cover Unit
Cover the Advantage Gelcoater with clean plastic sheeting to protect the
system.
NOTE
If the filter is difficult to unscrew by hand, use a strap
wrench or a chain wrench to prevent damage to the
filter.
CAUTION
Always wear approved eye protection when working
near pressurized equipment.
44