Owner manual
Advantage Gelcoater
9
Attach an airline between the air regulator and the fitting (marked βINβ) on
the flush tank (see Figure 5).
Figure 5: Air Supply Hose to Flush Tank
Install Main Air Line
Install the main airline (minimum 1/2β diameter) between the Advantage
Gelcoater and an air compressor capable of at least 10 cfm (0.3 cm.).
Install Catalyst Jug
Place catalyst jug into catalyst jug bracket.
Attach catalyst feed line (1/2β poly tube with clamps) from the barbed
nipple on the bottom of the catalyst jug to the catalyst pump inlet fitting
(See Figures 6 & 7).
NOTE
Do not turn on the air supply at this time. You will be
instructed when to do so.
WARNING
Never grease any part of the catalyst system. Use
only clean water for cleaning.