Specifications
WAVEFORM MONITORS/VECTORSCOPES
TEST EQUIPMENT
520
Leader has been manufacturing test and measurement equipment for forty years. The electronic instruments they design and manu-
facture are the standard of excellence against which others are measured for reliability, performance and cost effectiveness. Before a
product is brought to market, an exceptional degree of energy and effort goes into its design. Prototypes are built and tested to with-
stand environmental and other factors, far exceeding actual operating conditions. These include high humidity, extremes of heat,
cold, shock and vibration. Manufacturing quality is built in every step of the way. Only the finest parts are used, for optimum relia-
bility. At each production run, subassemblies are separately tested before they are integrated into the finished product. Then, each
product is tested again. This is why less than half of one percent of all Leader products are ever returned for repair or adjustment
.
LEADER
■ The timing display automatically displays a bow
tie pattern for precise measurement of interchan-
nel timing errors.
■ A four-page menu offers user-friendly setup to
select the proper mode of operation.
■ System selection sets sweep rates to operate with
525/60, 625/50 or 1125/60 (HDTV) systems.
■ On-screen cursors with front panel position con-
trols allow easy and precise measurements of
voltage or time spans on observed Waveforms.
The Preset mode stores the 5100's front-panel
setup conditions for instant recall.
■ Bandwidth of all four vertical channels extends
to 30 MHz to accommodate HDTV signals in
the Flat filter mode selection.
■ Low-Pass filter and Differential-Step modes facil-
itate linearity measurements in all four channels.
■ On-screen cursors with front panel position con-
trols allow easy and precise measurements of
voltage or time spans on observed Waveforms.
The Preset mode stores the 5100's front-panel
setup conditions for instant recall.
■ Universal power supply accepts 90-250v AC,
48-440 Hz as well as 12v DC power.
5100 Analog Component/Composite and HDTV Waveform Monitor
We are on the web at: www.bhphotovideo.com
LV-5100D/LV-5100DE
Serial Digital and Analog Component/Composite Waveform Monitors
Working in serial digital component (SDI 4:2:2) as well as analog component and composite (and mixed oper-
ations), the LV-5100D/LV-5100DE provide comprehensive waveform, vector, timing and picture monitoring
capabilities. Menu-driven control functions extend familiar waveform
observations into highly specialized areas and include local calibration
control, to show or blank SAV/EAV signals, the ability to monitor digital
signals in GBR or YCbCr form, line select (with an adjustable window),
memory storage of test setups with on-screen labels, flexible cursor mea-
surements, automatic 525/60 and 625/50 operation and much more.
LV-5100DE Adds ‘Eye Pattern’:
The LV-5100DE adds an equivalent-time sampling technique to display the SDI Waveform for analysis of
Amplitude, Phase, Frequency and Jitter effects on 270 Mb/sec data stream.
■ Analog composite and component
■ 4:2:2 Serial Digital Component (SDI)
■ Component Vector Display
■ Digital Signal-Status Readout
■ Analog video out (BNC x3)
■ Picture Display of Y or G
■ Overlay, Parade and Timing Waveforms
■ X-Y Stereo Display
■ Full line select with strobe on picture
■ Preset/recall of 10 front panel setups
■ Active serial output of selected A or B
serial input
A four-channel waveform monitor, the 5100 monitors the three channels associated with component opera-
tions and adds the fourth channel for simultaneous composite observations. Waveforms may be observed in
both overlaid and parade forms. A vector display shows chroma signal accuracy at a glance.
LV-5100DU Serial Digital Waveform Monitor
■ Same as LV-5100D without analog capability