Operator`s manual
Command Codes (AVM-510A)
E-9
VCR LOCK SET ‘Y’N<CR> N = 0 for crystal lock (narrow)
N = 1 for VCR lock (wide)
SC/H PHASE
DISPLAY SET
‘Z’N<CR> N = 0 for off
N = 1 for on
COLOR FRAME
SET
‘F’N<CR> N = 0 for off
N = 1 for on
VITC TIME CODE
SET
‘J’N<CR> N = 0 for off
N = 1 for on
GRATICULE SET ‘A’N<CR> N = 0 for off
N = 1 for on
N = 2 for added marks off
N = 3 for added marks on
PAL GRAT
PERCENT SET
‘6’N<CR> N = 0 for volts
N = 1 for percent
REDUCED SIZE SET ‘U’N<CR> N = 0 for waveform only
N = 1 for vector only
N = 2 for for both waveform and vector
MEASURE SET
SELECTED
‘S’N<CR> N = 0 for color set
N = 1 for non linear set
N = 2 for freq set
N = 3 for auto set
N = 4 for txmtr set
AUDIO METER ‘E’N<CR> N = 0 for entire meter off
N = 1 entire meter on
IMAGE RECALL ‘R’N<CR> N = 0 for image 1
N = 1 for image 2
N = 2 for image 3
N = 3 for image 4
N = 4 for image 5
N = 5 for image 6