Operator`s manual
Command Codes (AVM-510A)
E-4
KNOB TURN ‘K’N. .N<CR> N. .N = [0. .63]
The bits of this number are as follows:
BIT0 V0 – V0 & V1 are velocity bits
BIT1 V1 – 00 = slowest; 11 = fastest
BIT2 (not used, leave at 0)
BIT3 N0 – N0 & N1 are the knob selector
bits
BIT4 N1 – 00 = VPOS; 01 = HPOS
10 = MENU/VGAIN/LINESEL
PHASE
11 = (not used)
BIT5 Set for clockwise rotation; clr
for counter (anti) clockwise
rotation
Example: K43<CR> is a fast clockwise rotation of the H Pos knob.
H POS SET ‘H’N. .N<CR> N. .N = [0. .999]
This is a normalized position, that is, a value
of 500 would put the slider in the middle of
the range. 0 is all the way to the left; 999 is
all the way to the right.
V POS SET ‘V’N. .N<CR> N. .N = [0. .999]
This is a normalized position, that is, a value
of 500 would put the slider in the middle of
the range. 0 is all the way to the bottom; 999
is all the way to the top.
VAR GAIN SET ‘G’N. .N<CR> N. .N = [0. .255]
0 = most gain
255 = least gain
SELECTED LINE
SET
‘L’S. .S<CR> Also see SELECTED LINE REQUEST
The string has the form:
“1/3:123”
“1/3” an odd field
“123” line 123