Operator`s manual
C-1
C
C. Memory Locations
Introduction
This appendix lists the factory set memory locations for the MM-410 Waveform/Vector Rasterizing
Monitor (MM-410) and the AVM-510A Series Automated Video Monitors (AVM-510A). To make a
change, follow the procedure described in “Saving Settings.”
Saving Settings in Memory
After you configure the MM-410/AVM-510A, you need to save it in memory. The following
procedure explains how to store an MM-410/AVM-510A configuration in a memory location using
the Config (Configure) menu.
1. Select the desired signal input by pressing the Input button or through the Config menu options.
2. Configure the MM-410/AVM-510A for a desired mode.
3. Using the Vertical and Horizontal Position knobs, center the display.
4. Press the Config button to access the Config menu.
5. Using the arrow buttons, select MEMORIES and then press the Enter button.
6. Using the Arrow buttons, select STORE MEMORY.
7. Using the knob, select the desired memory location (1 through 10).
8. Press the Enter button to store that memory.
9. Press the Clr Mnu button to exit.
10. If you intend to view signals of several different formats, save them in other available memory
locations using steps 1 through 8.
NOTE:
Settings for other formats or standards are also stored. For example, (1) the +V
SWITCH ON/OFF setting for PAL even when memory is stored for NTSC and (2) limit
settings for both standards are stored.