Introduction (AVM-510A-C)
The AVM-510A-C includes a component measurement set and a digital measurement set when an
SDM-550 is interconnected.
Component Measurement Sets (AVM-510A-C)
Setting limits for component signals SMPTE/EBU, Beta, MII, and RGB can only be done when
Input B: is active and is configured for a component signal.
To change the Input B: selection to component:
1. Press the Config button.
2. Select INPUT and then press the Entr button.
3. Select INPUT B: and then press the Entr button several times (or rotate the knob) until the
component system you want appears on the display.
NOTE:
The AVM-510A-C can have different limits for each of the four component signal
standards.
4. Press the Clr Mnu button to exit.
To set the component limits:
1. Press the Mesmnt button.
2. Select SELECT SET and then press the Entr button.
3. You should now only see one item COMPONENT. Press the Entr button to continue.
4.
Select MEASURE LINE and then turn the knob to select the line which has the signal. Note that
this might be in the active area or in the vertical interval. You can also switch from one field to
another by turning the knob or by pressing the Field Select button.
5.
Select SIGNAL ID and then press the Entr button several times to select one of the following:
AUTO SIG ID this signals the AVM-510A-C to determine what the signal is and apply that
measurement set.
LIVE VIDEO this choice shuts off all the parameters except those that are appropriate for live
video measurement.