Operator`s manual
Measurement Screens (Parameters and Limits) (AVM-510A)
10-4
EBU/SMPTE Component Measurements (A/B Inputs)
Measured Parameter Definition
Y ampl Y (luminance) amplitude.
B-Y ampl B-Y color difference signal amplitude.
R-Y ampl R-Y color difference signal amplitude.
Sync ampl Sync amplitude (as encoded back onto signal).
Peak video Peak of the luminance signal.
H timing Ref Timing of input signal relative to Ext Ref.
B-Y to Y Timing of B-Y relative to Y component.
R-Y to Y Timing of R-Y relative to Y component.
Audio
Measured Parameter Definition
1 left
(1)
Upper and lower limits with alarm delays for each.
1 right
(1)
Upper and lower limits with alarm delays for each.
2 left
(1)
Upper and lower limits with alarm delays for each.
2 right
(1)
Upper and lower limits with alarm delays for each.
(1)
The same for both