Operator`s manual
Automatic Measurement (AVM-510A)
9-8
9. Press the Entr button to move the cursor to the MIN column and then turn the knob to set the
minimum acceptable value.
10. Press the Entr button to move the cursor to the MAX column and then turn the knob to set the
maximum acceptable value.
While in the MIN and MAX columns, the Arrow buttons switch the cursor back and forth
between them. Pressing the Entr button moves the cursor from MIN to MAX, or from MAX out
and down to the next parameter name (step 8). Pressing the Prev Mnu button moves the cursor to
the parameter in the current row.
11. After setting all acceptable values, press the Clr Mnu button to exit or press the Prev Mnu
button twice to go back and select another measurement set.
NOTE:
Composite and S-video limits are the same. Whatever limits are set for Input A:
composite using a 625 signal in the Color Setup limits will also be used when Input A:
detects an S-video 625 signal and the Color Setup measurement set is used.
Special Considerations for MultiBurst
The AVM-510A recognizes two standard multiburst signals (FCC multiburst in NTSC and CCIR 18 in
PAL) but can also be set up to automeasure a non-standard multiburst signal. If you want to
automeasure a multiburst signal, you need to set the AVM-510A up to detect either a standard
multiburst or a custom multiburst signal. The following table lists all the applicable combinations.
Automeasurement Setup Applied Signal
Controlling
Measurement
Set
Multiburst ID
Setting
Frequency
Response
Signal ID
Setting
FCC
Multiburst
CCIR 18
Multiburst of
Another Type
What the AVM-510A Recognizes
AUTO
MEASURE/
AUTO MEAS
SET
Auto detect Any setting FCC
multiburst
CCIR 18 Multiburst
AUTO
MEASURE/
AUTO MEAS
SET
Standard Any setting FCC
multiburst
CCIR 18 CCIR 18 or
FCC multiburst
AUTO
MEASURE/
AUTO MEAS
SET
Custom Any setting Custom Custom Custom
Frequency
response
Auto detect
AUTO SIG ID
FCC
multiburst
CCIR 18 Multiburst
Frequency
response
Standard
AUTO SIG ID
FCC
multiburst
CCIR 18 CCIR 18 or
FCC multiburst
Frequency
response
Custom
AUTO SIG ID
Custom Custom Custom
Frequency
response
Any setting CCIR 18 or
FCC multiburst
FCC
multiburst
CCIR 18 CCIR 18 or
FCC multiburst
Frequency
response
Any setting Multiburst Custom Custom Custom