5.4.2 Programming & Other RCP Software Functions
NOTE: To program or read data from the CAN-2 the receiver must be turned on.
Saving the Programming File
Once programming is complete click the file tab at the top of the RCP screen to open the file
menu. File location and name can be selected from this menu. Old files can be deleted, called
up, modified and renamed by this same menu.
Sending a Program to the CAN-2
WARNING
AFTER EVERY PROGRAMMING OF THE RECEIVER, TEST THE UNIT BY UTILIZING THE
APPROPRIATE TRANSMITTER. IF THE RECEIVER DOES NOT RESPOND, DO NOT ACTIVATE A
FUNCTION BUTTON! THE RECEIVER MAY HAVE INCORRECT PROGRAMMING. RE-CHECK THE
PROGRAMMING IN THE RECEIVER AND RETEST. AFTER ACTIVATION OF THE RECEIVER,
FUNCTIONALLY TEST ALL COMMANDS ON THE TRANSFORMER BY INITIALLY JOGGING THE
BUTTONS, THEN WITH A FULL MOVEMENT BEFORE RETURNING TO SERVICE. FAILURE TO
FOLLOW THIS WARNING COULD RESULT IN SERIOUS INJURY OR DEATH AND DAMAGE TO
EQUIPMENT.
To send a program file to an CAN-2 Receiver
1. Plug in the USB programming cable or position.
2. Click the send button on the RCP screen. A dialog box will pop up confirming that you
want to proceed. Check the box marked “I accept,” and then click the button “Continue
send to radio.” On-screen prompts will confirm that the receiver has been programmed
or if there are any issues.
3. Data will need to be sent separately for the Unit Info and CAN Configuration screens.
4. The LEDs on the unit will blink three times when the new data is received and saved.
Receiving (Reading) the CAN-2 Programming
To read a program file from the CAN-2 Receiver:
1. Plug in the USB programming cable.
2. Click “Receive” and follow on-screen prompts.
3. RCP will confirm reception and automatically display current programming in the CAN-2
unit.