Technical information
Enrange CAN-2 Instruction Manual
January 2014
Page 14 of 33
Figure 10: CAN-2 Machine Stop Wiring
Additionally, make sure that a Machine Stop is provided elsewhere on the equipment in which the
CAN-2 is installed in order to comply with all applicable Machinery Directives.
CAN (Pins 1, 2, 4, and 5)
There is only one CAN bus on the CAN-2. There are 2 sets of pins to support proper daisy
chained connections to a CAN network.
CAN Reference (Pin 3)
On isolated CAN-2 devices pin 3 should be connected to the common pin of the device using the
isolated CAN bus. On non-isolated CAN-2 units this pin can be connected to the system
common.
3.8 CONNECTOR COMPONENT INFORMATION
Table 2: Connector Part Numbers
DEUTCH Connector Information DEUTCH Part # Magnetek Part #
Connector Housing
DTM06-12SA 01-525-0029E
Wedge Lock
WM-12S 01-525-0030E
Crimp (16-22 AWG)
1062-20-0122-PS 01-550-0029E
Connector Boot
DTM12S-BT (Gray) 20-990-0092E
Connector Kit (all components
above)
N/A 25-04-030-163E
CAN RX 6’ Harness Assembly
N/A 25-04-030-173E