3.4 REMOVAL OF CAN-2 FROM HOUSING
It might be necessary to access the internal circuit board on the receiver to adjust the
CAN terminating resistor jumper.
To remove the CAN-2 receiver from the housing, first remove power from the CAN-2
receiver by turning off the master disconnect. Remove the connectors from the bottom of
the receiver by squeezing in the release tabs on both sides of the connector. The bottom
connector plate with the internal circuit board is removed by inserting a flat screwdriver
into the top slots for the two side release tabs and giving a gentle twist.
Figure 06: CAN-2 housing removal procedure
After releasing both sides, one at a time, gently pull the circuit board from the housing