Installation guide
36 Specifications
5.8 – Digital I/O Board
The Digital I/O-BCD board has been designed to inter-
face to switches and/or relays. There are 24 optically
isolated inputs and 16 optically isolated outputs per
board.
If the MX2000 controller is an MX2A or MX6A the first
digital I/O board is the Power supply board and there are
16 inputs and 8 outputs available (101-116). Up to 4
boards can be interfaced to an MX2000-8 controller. The
ID for each board is selected via 2 dip switches located
on the board.
5.8.1 – Input Connector
This connector has 24 optically isolated inputs that can be
configured for current sinking or sourcing. The sink-
ing/sourcing selection is done on the digital I/O card us-
ing jumpers. The factory setting is sinking.
Note: The movement of both jumpers is required for
proper operation. If only one jumper is moved the
digital inputs and outputs modes will be different.
Inputs
Signal Name Description Electrical Specification
B01 to B24 IN (B01-B24)
Sink Mode: On state 0 to +12 volts, On state current 2.3 ma @ +12v, 6.5 ma @ 0v.
Source Mode: On state +10 to +24 volts, On state current 2.3 ma @ +10 volts, 6.5 ma
@ +24 volts.
Where: B is the board number, 1 through 4.
Header
Pins
Jumpers
J7 J7
Jumper Positions
for
Sourcing I/O
Jumper Positions
for
Sinking I/O
INPUTS
1,2,13,14
3,4,15,16
5,6,17,18
7,8,19,20
9,10,21,22
11,12,23,24
24V
24V
COM
COM
INPUTS
1,2,13,14
3,4,15,16
5,6,17,18
7,8,19,20
9,10,21,22
11,12,23,24
24V
24V
COM
COM