FOLSYNCDIST Following Parameter
ACTION: Specifies the master distance to travel when a FOLOFFSET
command is issued. This distance will be traveled before the
FOLOFFSET command is executed.
PROGRAM SYNTAX: FOLSYNCDIST(axis)=expression
FOLSYNCDIST(axis)=expression1, ... , expression8
FOLSYNCDIST(axis) - used in an expression
FOLSYNCDIST(axis, ... ,axis)=expression, ... ,expression
REMARKS: The axis specifies the number of the following axis (1-8).
The expression specifies the master distance traveled.
Used in conjunction with the FOLOFFSET command to specify
the in synchronization master distance traveled during a
FOLOFFSET cycle.
EXAMPLES: FOLSYNCDIST(2)=.5
sets the master distance traveled for axis 2 to .5 units.
FOLSYNCDIST(1,3)=.5,.6
sets the master distance traveled for axis 1 to .5 units and the
master distance traveled for axis 3 to .6 units
FOLSYNCDIST=.5,,.6
sets the master distance traveled for axis 1 to .5 units and the
master distance traveled for axis 3 to .6 units
250%
Master
Velocity
100%
-50%
0%
FOLOFFSET(axis) = 3
FOLOFFSETDIST(axis) = 4
ADVANCE CYCLE
FOLOFFSET(axis) = -3
FOLOFFSETDIST(axis) = 4
RECEDE CYCLE
FOLSYNCDIST(axis) = 1