Technical data
2.6.4.2 Removers for polysulfide primers 6850-01-495-
0150 (55 GL DR), 6850-01-495-0149 (5 GL), 6850-01-495-
0235 (1 GL).
Part Number Source of Supply
CeeBee E-1058 &
E-1058A
CeeBee Div, McGean-Rohco Inc.
Cage Code: 8U841
1314 Murphy Ave.
Atlanta, GA 30310-4004
SR-125A, SR-145,
& PR-3133
Eldorado Solutions, Inc.
Cage Code: 55208
11611 N Meridian
ST, STE 600
Carmel, IN 46032
DBA of Eldorado Chemical CO Inc.
5151B B&B Tritech, Inc.
Cage Code: 21361
875W20
th
St
Hialeah, FL 33010-2310
D-Zolve GL-15-33 Solvent Kleene, Inc
Cage Code: 0L8C9
119 Foster St, Bldg 6
Peabody, MA 01960
2.6.5 Chemical Remover Selection For Depot Re-
moval Operations. Each Air Logistics Center (ALC),
either alone or in concert with other ALC’s shall prepare a
purchase description (PD) with a qualified products list
(QPL). This QPL will establish testing and qualification
procedures for removers authorized for use in their facilities
from among those listed in Paragraph 2.6.2.1, Paragraph
2.6.2.2, Paragraph 2.6.4.1, Paragraph 2.6.3, and Paragraph
2.6.4.2. Testing for removers in Paragraph 2.6.2.1, Paragraph
2.6.2.2, and Paragraph 2.6.4.1 shall include removal effi-
ciency tests from test panels with one coat of epoxy or
polyurethane primer and two coats of epoxy or polyurethane
topcoat air dried for seven days at room temperature and then
baked for 4 days in an oven at 210° F (± 10° F). Efficiency
tests from removers in Paragraph 2.6.3 and Paragraph 2.6.4.2
will be conducted on test panels with one coat of polysulfide
primer (PR-1432GV) and two coats of polyurethane topcoat
air dried for seven days at room temperature and then bake
for 4 days in an oven at 210° F (± 10° F). Criteria for passage
of the test shall be complete removal to bare metal in 15
minutes maximum for phenolic removers, one hour for
nonphenolic/non-cresylic removers, and one hour using just
removers listed in Paragraph 2.6.3 and Paragraph 2.6.4.2.
Criteria for polysulfide primer is complete removal to bare
metal in 30 minutes maximum using these same removers
after the topcoat is removed using a removers listed for epoxy
and polyurethane finish systems. It should be understood that
removal time for a finish system which has been in service for
several years is somewhat longer than for removal of the
same finish system from test panels prepared as noted above.
Removal time is also dependent on the number of overcoats
present on the surface and environmental conditions in the
removal facility.
TO 1-1-8