User guide
156
}
A
B
Dual Control Module – DCM acts
as the application control device in
CAN control systems. Each DCM can
control two separate products.
Switch Function Module – SFM
controls boom sections either
manually or automatically. Each SFM
can control up to 10 boom sections
Boom Switchbox or Input Status
Module (ISM) – These devices
connect to the CAN-bus and allow the
system to know when boom sections
are turned on and off by the operator.
The ISM connects to existing boom
switches in a joystick or console,
while the Boom Switchbox has its
own boom switches. Both devices
can be used with the Switch Function
Module for manual or automatic
boom section control.
Hydraulic Control Valve and Cables
See page 166 for hydraulic control
valve details.
Application Rate Sensor and
Cables
See page 134 for application rate
sensor details.
Speed Sensor and Cables
See pages 164 and 165 for speed
sensor details.
GPS Receivers and Cables
See page 125 for GPS receiver details.
Sensor
B
Sensor
A
Adapter Cable
402-0065
Rate Sensor
120-0009
Dual Control
Module
78-08025
Terminator
45-08102
(a)
DCM Harness
45-07500
To
Battery
Compact II Radar
90-02168
Spinner & Conveyor
Sensor Cable
45-05141
Fan Sensor
16-05000
Optional
Power
Cable
45-05381
(a)
Fieldware Tools Software
90-02061 (a)
RX 370p
GPS Receiver
78-50148
GPS Adapter
Cable
45-05340
Input Status
Module
45-07602
(c)
Implement
Status
Swath Manager
Engage/Disengage
Boom
Sense (10)
L6K Main
Harness
45-07000 (a)
Legacy 6000 Console
75-05007 (a)
Com 1
Com 2
To
Battery
Terminator
45-08101
(a)
USB
CAN Extension
Cable (12’/4m)
45-08112
EXR-IV
Hydraulic Control
Valve
Valve
Extension Cable
402-0024
Application Harness
45-06502
Legacy
RAM Bracket
90-02161 (a)
Data Card
78-50049 (a)
Optional Items
Lightbar
78-50140 (b)
Power In
+12v
Remote Power Switch
for GPS Receiver
78-00030
Legacy 6000
®
Granular System
MOBILE ELECTRONICS
ENGLISH
Legacy 6000 CAN System Checklist—Basic Granular System
PART
NUMBER
DESCRIPTION
Console Kits
90-02366
Legacy 6000 Kit, Basic
(contains parts identified in the system diagram with an (a))
90-02367
Legacy 6000 Kit, Basic with Lightbar
(contains parts identified in the system diagram with an (a) and (b))
90-02368
Legacy 6000 Kit, Basic with Lightbar and ISM
(contains parts identified in the system diagram with an (a), (b) and (c))
99-01009
License for Multiple Product Variable Rate Applications
(not required for non-VR Multiple Product, or for Single Product VR)
Boom Switchboxes and
Input Status Modules
45-07602 ISM, 10 Boom
78-30009 Boom Switchbox, Booms 1–5
78-30004 Boom Switchbox, Booms 1–10
Switch Function Module
78-08027 SFM, Booms 1–10
45-05302 SFM Power Cable with Metripack Connector (one required per SFM)
DCM and Power/Speed Harness
78-08025 DCM with Fieldware
45-07500
DCM Harness with CAN, Power and Speed Connections
(one required per DCM)
DCM Application Control Harnesses
(one required per product)
45-06501 DCM Product Harness, Servo Valve + One Frequency Type Sensor Input
45-06502 DCM Product Harness, Servo Valve + Two Frequency Type Sensor Inputs
CAN Extension Cables
45-08106
68 CAN Extension Cable
45-08112
128 CAN Extension Cable
45-08117
208 CAN Extension Cable
45-08118
308 CAN Extension Cable
Power Cables
(Standard 2-Position Weatherpack)
401-0016
Battery Cable, 28, 1 Lead
45-05037
Battery Cable, 28, 2 Lead
401-0011
Battery Cable, 28, 3 Lead
45-05381
Battery Cable, 128, 3 Lead with Fuses
45-05160
108 Power Extension Cable, Fused
45-05161
208 Power Extension Cable, Fused
45-05162
308 Power Extension Cable, Fused
Fieldware Office Software 90-02061 Fieldware Office Software CD and Manual
GSO