Touchless
3
75.5820.02 MS-11 20160106 Page 3 of 4
SETTINGS & ADJUSTMENTS
DETECTION ZONE - potentiometer
COUNTERCLOCKWISE - decrease (2’’ minimum)
CLOCKWISE - increase (24’’ maximum *)
OUTPUT TIME - potentiometer
COUNTERCLOCKWISE - decrease (1 s minimum)
CLOCKWISE - increase (30 s maximum)
AUDIBLE CONTROL - 2-pin jumper
ON - jumper removed (or on 1 pin)
OFF - jumper over both pins
OUTPUT MODE - 2-pin jumper
TIMED - jumper removed (or on 1 pin)
TOGGLE - jumper over both pins
* Maximum Detection Zone will vary depending on size (area), orientation, and
speed of object as well as environmental conditions.
A
B C
FUNCTIONALITY
AUDIBLE ALERT - When Audible Alert is ON, it sounds for 0.5 seconds when detection occurs.
TIMED MODE - Recommended for automatic door applications. In Timed Mode, a detection
activates the relay and the relay holds for a predetermined amount of time adjusted by the Output
Time potentiometer (1 to 30 seconds, counterclockwise - decrease, clockwise -increase).
TOGGLE MODE - Recommended for switch applications. In Toggle Mode, a detection activates the
relay and a second detection deactivates the relay. The relay will hold indenitely until a second
detection occurs.
4
SETUP & OPERATION
When rst powered, the backlit hand symbol will alternate between blue and green for
approximately 5 seconds. Allow at least 15 seconds for the sensor to complete start up.
During normal operation, when a detection occurs, the hand symbol will momentarily change
from blue to green and the audible alert will sound (if enabled).