Installation guide

17
Figure 20
Figure 19
Figure 18
CAUTION: Failure to follow instructions could result in serious injury.
Shut-Off the Range
1. Turn the manual shut-off valve to the
closed position.
2. Unplug range or disconnect power.
How to Convert Gas Pressure Regulator (Natural Gas to LP Gas)
Manual Shut-Off Valve
“Closed” Position
To Range
Gas Supply Line
b
c
a
a
d
d
e
e e
e
1. Remove plastic cover from gas pressure regulator cap.
2. Turn gas pressure regulator cap counter-clockwise with a 5/8” wrench to remove.
NOTE: DO NOT remove the spring beneath the cap.
3. Remove the retainer pin that is currently positioned for use with Natural Gas.
4. Turn the retainer pin upside down and re-install into the regulator cap. It is now positioned for use with LP Gas.
5. Screw the regulator cap back into the regulator and reattach the regulator to the nipple and flare union.
How to Convert Gas Pressure Regulator (Natural Gas to LP Gas)
a. Plastic cover
b. Gas pressure regulator
cap with solid end
facing out
c. Gas pressure regulator
cap with hollow end
facing out
d. Washer
e. Gas pressure regulator
cap
Section View
Section View
1. Remove the burner grates, burner
caps and burner heads.
2. Using a 7 mm nut driver, remove the
burner orifices.
3. Install the proper orifices in replace
of the ones that were removed.
4. Re-install the burner bases, heads and
top grates. Make sure the burner caps
are properly seated on the burner
heads.
Triple Ring Burner
5 Orifices
Auxiliary Burner, Semi-Rapid Burner,
Repid Burner: 1 Orifiece Each
Orifieces