Configuration Mode-2, Video Coupling: Select AC or DC coupling, and DC-restore functions, to be applied to the input video.
(starting in normal-mode) Press and release the CFG button twice to access configuration-mode-2. CFG indicator = flashing.
Press and release the SEL button once. You will now be able to change video-coupling settings.
LED indicators 1-2 should be illuminated (either DIM or ON); all others (indicators 3-8) should be off.
Press the CFG button repeatedly to step through the available video-option settings as shown below.
To leave configuration-mode step through all the options OR leave the buttons untouched for 10 seconds.
LED1
LED2
Front Panel View
Video Options Mode
dim
dim
Auto-detect AC/DC coupling mode based on input signal.
This is the factory-default mode.
dim
ON
Video-input is DC coupled.
ON
dim
Video-input is AC coupled, no DC-restore function.
ON
ON
Video-input is AC coupled, DC-restore function enabled.
Configuration Mode-2, Video Termination: Select input video termination to be 75 ohms or high-impedance (Hi-Z).
(starting in normal-mode) Press and release the CFG button twice to access configuration-mode-2. CFG indicator = flashing.
Press and release the SEL button twice. You will now be able to change video-termination settings.
LED indicator 3 should be illuminated (either DIM or ON); all others (indicators 1, 2, 4-8) should be off.
Press the CFG button repeatedly to toggle video termination on/off, as shown below.
To leave configuration-mode step through all the options OR leave the buttons untouched for 10 seconds.
LED3
Front Panel View
Video Options Mode
dim
Video input impedance is Hi-Z.
ON
Video-input impedance is 75-ohms. This is the factory-default setting.
To reset all user-configurable options back to factory-default settings:
Disconnect the DC power cable (or AC power).
Press and hold the CFG button.
Connect the DC power cable (or AC power). All LEDs blink 3 times – all settings are now changed back to factory-defaults.
Release the CFG button.
Troubleshooting: In many cases, problems encountered when installing MultiView™ II extension products can be resolved by
checking the CAT5 cable termination. It must be pinned out according to the TIA/EIA 568B standard wiring specification. For additional
troubleshooting information or to obtain the TIA/EIA 568B wiring specifications please refer to the MVII-XRTx User Guide,
downloadable from www.tvone.com