Setup guide

16
MAGENTA MULTIVIEW™ SERIES
14
Appendix B. AK600 Configuration Settings
Note: AK600 receivers are typically pre-configured at time of order and will have factory
configuration indicated on the bottom of the unit.
The factory configuration may be changed or checked by using the following jumper
location diagram as well as Table B-1 for jumper settings.
Figure B-1. AK600 Jumper locations.
AUTO SYNC MODES:
JP8 controls sync clamping circuitry and works with the external switch labeled
AUTO CLAMP.
The default sync mode is AUTO CLAMP OFF which will autosense between
RGBHV and non-RGBHV signals.
Turning the External AUTO CLAMP switch ON will set the sync clamp mode to
RGBHV video modes
If non-RGBHV video is desired with AUTO CLAMP ON, jumper JP8 must be set
to IN.