Specifications
90
Static Survey Setup (Base and Rover)
1. Turn on the receiver by pressing the red key. Wait for
the ProMark3 workspace to appear on the screen.
2. Double-tap the Surveying icon to run the Surveying func-
tion. The screen displays the navigation screen that was
last displayed.
3. Make the settings required when first using the Surveying
function:
• Press the MENU key
• Tap Setup. In the Setup menu, tap successively the
options you need to set. Remember you need to define
the Storage medium (internal memory or SD card) and
the Receiver ID. If you have a ProMark3 RTK, press
the MENU key again, tap
Receiver Mode and then
select Post-Processing. Skip step 3 when next using the
Surveying function.
4. Press the NAV key until you see the Satellite Status screen
(see opposite).
Wait until at least 4 satellites are received.
5. When there is enough satellites received, press the LOG
key. The Survey Settings screen opens.
Satellite Status screen