Owner manual

Item Specifications Test conditions
Low There must be no case deformation Inductors shall be subjected to temperature
temperature or change in dimensions.
-40±2 for 48±12 hours.
storage Inductance must not change more Measure the test items after leaving the
than the stated tolerance. inductors at room temperature and humidity
for 1 to 2 hours.
Resistance to There must be no case deformation, Inductors must withstand 6 minutes of
solvent change in dimensions, or alcohol or water.
obliteration of marking.
Thermal There must be no case deformation Inductors shall be subjected to 10 cycles
shock or change in dimensions. to the the following temperature cycle:
Inductance must not change more
than the stated tolerance.
Measure the test items after leaving the
inductors at room temperature and humidity
for 2 hours.
MHQC-2520C-SERIES Page-4/7
MAG.LAYERS
-40
+125
30 min.
30 min.
1 cycle
30 sec